Unidrive SP Regen Installation Guide
69
Issue Number: 2 www.controltechniques.com
Figure 6-4 Unidrive SP size 4, 5 and 6 power connections
.
U
V
W
AC supply connections
L1
L2
L3
+DC
-DC
Internal
EMC filter
*
4
(Refer to Chapter 4
)
L1, L2, L3
System design
To be
removed
PE
*
DC Connections
(High current DC
to motoring drive[s])
5 6
U
V
W
L1
L2
L3
+DC
-DC
Internal
EMC filter
*
4
PE
*
5 6
To be
removed
Motor
Optional ground
connection
Regen
drive
Motoring
drive
Vac supply