Safety
Information
Introduction
Product
information
System
design
Mechanical
installation
Electrical
installation
Getting
started
Optimisation
Parameters
Technical
data
Component
sizing
Diagnostics
72
Unidrive SP Regen Installation Guide
www.controltechniques.com Issue Number: 2
Figure 6-7 Unidrive SPMC power connections
.
U
V
W
AC supply connections
+DC
-DC
Internal
EMC filter
*
To be
removed
PE
*
DC Connections
(High current DC
to motoring drive[s])
5 6
U
V
W
+DC
-DC
Internal
EMC filter
*
PE
*
5 6
To be
removed
Motor
Optional ground
connection
Regen
drive
Motoring
drive
Vac supply
L1
L2
L3
SPMC
PE
+DC
-DC
PE
Used as only
softstart
Motor connections
SPMD
SPMD
Summary of Contents for SP1201
Page 219: ......
Page 220: ...0471 0029 02 ...