18
Reference Manual
00809-0100-4024, Rev CA
Mechanical Installation
March 2020
Mechanical Installation
This product is an electrical apparatus and must be installed in the hazardous area in accordance with
the requirements of the EC Type Examination Certificate.
The installation and maintenance must be carried out in accordance with all appropriate international,
national and local standard codes of practice and site regulations for intrinsically safe apparatus and in
accordance with the instructions contained within this manual. Access to the circuitry must not be
made during operation.
1. The product has been designed such that the protection afforded will not resistance and the affects
of temperature variation.
2. The product can not be repaired by the user and must be replaced by an equivalent certified
product. Repairs should only be carried out by the manufacturer or approved repairer.
3. The product must be protected from excessive dust by an enclosure etc.
4. The product must not be subjected to mechanical and thermal stresses in excess of those permitted
in the certification documentation and the instruction manual. If necessary the product must be
protected by an enclosure to prevent mechanical damage.
5. There are no exposed parts of the apparatus which produce excessive surface temperature,
infrared, electromagnetic, ionizing radiation or non electrical dangers.
6. The product must not be installed in a position where it may be attacked by aggressive substances.
All externally connected equipment must comply with, or have isolation from mains complying with,
the relevant electrical safety standard. As a matter of routine, shut off the Model 5600 Radar Level
Transmitter and all other equipment in the tank before you enter the tank.
Failure to follow safe installation and servicing guidelines could result in death or serious injury:
Make sure only qualified personnel perform these procedures.
Use the equipment only as specified in this manual. Failure to do so may impair the protection provided
by the equipment.
Do not perform any service other than those contained in this manual unless you are qualified.
The quartz seal is not suitable for use in environments where there is a risk for variations or other
mechanical impacts.
For quartz seal, mechanical shocks may permanently damage the seal. A damaged tank seal must be
replaced. Replacement must be done when the tank is unpressurized.
The customer must always make sure that exposed material of antenna and tank seal is compatible with
the tank content (e.g. the quartz seal) is not suitable for use with Hydrofluoric acid (HF).
A damaged quartz tank seal will typically cause one or many disturbance echoes which will be seen in a
tank spectrum plot during gauge configuration.
Summary of Contents for Rosemount 5600 Series
Page 2: ......
Page 4: ...4 Reference Manual 00809 0100 4024 Rev CA Title Page March 2020 Title Page ...
Page 16: ...16 Reference Manual 00809 0100 4024 Rev CA Introduction March 2020 Introduction ...
Page 125: ...125 Reference Manual 00809 0100 4024 Rev CA Index March 2020 Index Strapping Table 71 ...
Page 126: ...126 Reference Manual 00809 0100 4024 Rev CA Index March 2020 Index ...
Page 127: ......