
Product Certifications
117
Product Certifications
March 2020
Reference Manual
00809-0100-4024, Rev CA
RD
BK
BU
GR
ISSUE
ISSUE
ISSUE
MODIF. ORDER NO.
MODIF. ORDER NO.
MODIF. ORDER NO.
WEEK
WEEK
WEEK
1
0210
SME-3006
SME-3148
2
0348
0722
SME-5704
3
ISSUE
ISSUE
ISSUE
MODIF. ORDER NO.
MODIF. ORDER NO.
MODIF. ORDER NO.
WEEK
WEEK
WEEK
1
0210
SME-3006
SME-3148
2
0348
0722
SME-5704
3
ISSUE
ISSUE
ISSUE
MODIF. ORDER NO.
MODIF. ORDER NO.
MODIF. ORDER NO.
WEEK
WEEK
WEEK
1
0210
SME-3006
SME-3148
2
0348
0722
SME-5704
3
ISSUED BY
APPROVED BY
WEEK
WEEK
PRODUCT CODE
DOC. TYPE
FILE
TITLE
DWG NO.
ISSUE
SHEET
SCALE
1 ST ANGLE
FINISH, UNLESS
OTHERWISE STATED:
The copyright/ownership of this document is and will remain ours.
The document must not be used without our authorization or brought
to the knowledge of a third party. Contravention will be prosecuted.
Rosemount Tank Radar AB, Sweden
ALL DIMENSIONS ARE IN MILLIMETRES.
TOLERANCES, UNLESS OTHERWISE STATED:
GU-MK
0210
PRO/5600
GP-HN
2
OrCAD
9150074-935
9150074-935
0210
INSTALLATION DRAWING EL.
For installation of SCS (ATEX)
3
1 / 1
approved apparatus (EEX e / EEX i)
ISSUED BY
APPROVED BY
WEEK
WEEK
PRODUCT CODE
DOC. TYPE
FILE
TITLE
DWG NO.
ISSUE
SHEET
SCALE
1 ST ANGLE
FINISH, UNLESS
OTHERWISE STATED:
The copyright/ownership of this document is and will remain ours.
The document must not be used without our authorization or brought
to the knowledge of a third party. Contravention will be prosecuted.
Rosemount Tank Radar AB, Sweden
ALL DIMENSIONS ARE IN MILLIMETRES.
TOLERANCES, UNLESS OTHERWISE STATED:
GU-MK
0210
PRO/5600
GP-HN
2
OrCAD
9150074-935
9150074-935
0210
INSTALLATION DRAWING EL.
For installation of SCS (ATEX)
3
1 / 1
approved apparatus (EEX e / EEX i)
ISSUED BY
APPROVED BY
WEEK
WEEK
PRODUCT CODE
DOC. TYPE
FILE
TITLE
DWG NO.
ISSUE
SHEET
SCALE
1 ST ANGLE
FINISH, UNLESS
OTHERWISE STATED:
The copyright/ownership of this document is and will remain ours.
The document must not be used without our authorization or brought
to the knowledge of a third party. Contravention will be prosecuted.
Rosemount Tank Radar AB, Sweden
ALL DIMENSIONS ARE IN MILLIMETRES.
TOLERANCES, UNLESS OTHERWISE STATED:
GU-MK
0210
PRO/5600
GP-HN
2
OrCAD
9150074-935
9150074-935
0210
INSTALLATION DRAWING EL.
For installation of SCS (ATEX)
3
1 / 1
approved apparatus (EEX e / EEX i)
1 2 3 4 5 6
INTR. SAFE / EEx ib/ia
SECONDARY OUTPUT (OPTION)
I.S. PRIMARY OUTPUT (OPTION)
–
+
X2
HAZARDOUS AREA
Three separate I.S. circuits
TRANSMITTER HEAD TH 43..
NON-HAZARDOUS
AREA
CABLE GLANDS EEx e
with integral cable shield connection for cable diameter 6-12 mm.
NOTE! Shielded cables required for specified EMC performance.
–
+
EEx de [ib/ia] IIC T6
GAS
GROUP
IIB
&
IIC
GAS
GROUP
IIB
&
IIC
EARTH
CONNECTION
Area: 4 mm².
DISPLAY PANEL (OPTION)
NON-HAZARDOUS AREA INSIDE
Ui < 30 V, Ii < 200 mA
Pi < 1,3 W
Ci = 0 µF, Li = 0 mH
ALT. 1:
PASSIVE CURRENT LOOP
ALT. 2:
ACTIVE CURRENT LOOP
Uo = 23,1 V, Io = 125,7 mA
Po = 0,726 W
Cext <0,14 µF, Lext <2,2 mH
Ui < 30 V, Ii < 200 mA
Pi < 1,3 W
Ci = 0 µF, Li = 0 mH
ALT. 3:
FOUNDATION FIELDBUS
ALT. 1:
PASSIVE CURRENT LOOP
X5
X6
X7
Uo = 23,1 V, Io = 125,7 mA
Po = 0,726 W
Cext <0,14 µF, Lext <2,2 mH
(EEx ib IIC T4)
NOTE 1: Transmitter Head is earthed locally on the tank for explosion protection and electrical safety.
A separate protective earth connection to the power distribution central is not recommended unless it is an
absolute requirement by national authorities. A ground loop with circulating current may occur.
X4
–
POWER
SUPPLY
4
+
X1
HART/4-20mA
or TRL2 Bus (TM 40 option)
or Profibus DP ( AA 40 option)
or Foundation Fieldbus ( FF 43
option )
L /L1/+
2
Nominal Input:
24-240 V DC/AC (0-60Hz)
max. 10 W.
Internal fuse link T 2.5A L 250V
Installation Category III.
A circuit breaker should be
installed close to the TR Pro
transmitter.
Min. cable area: 0.5 mm²
1
N/L2/–
3
NON IS
PRIMARY
OUTPUT
X3
NON IS / EEx e
PE¹)
7
Vcc
DB
Gnd
DA
ALT. 2:
ACTIVE CURRENT LOOP
Ui < 30 V, Ii < 300 mA
Pi < 1,3 W
Ci = 0 µF, Li = 0 mH
GAS
GROUP
IIB
&
IIC
DISPLAY OUTPUT (OPTION)
Uo = 7,84 V, Io = 385,6 mA
Po = 0,678 W
Cext < 8,8 µF, Lext < 0,17 mH
Voltage Compliance: 7-30 V
Max . Load: 300 Ohm
Max . Load: 300 Ohm
Voltage Compliance: 7-30 V
Summary of Contents for Rosemount 5600 Series
Page 2: ......
Page 4: ...4 Reference Manual 00809 0100 4024 Rev CA Title Page March 2020 Title Page ...
Page 16: ...16 Reference Manual 00809 0100 4024 Rev CA Introduction March 2020 Introduction ...
Page 125: ...125 Reference Manual 00809 0100 4024 Rev CA Index March 2020 Index Strapping Table 71 ...
Page 126: ...126 Reference Manual 00809 0100 4024 Rev CA Index March 2020 Index ...
Page 127: ......