22
Reference Manual
00809-0100-4024, Rev CA
Mechanical Installation
March 2020
Mechanical Installation
2.3.4
Beam width
Figure 2-4. Beam Width Angle, See
D. Minimum distance to tank wall
(1)
Antenna
Distance in. (mm)
Cone
24 (600)
Process seal
24 (600)
Parabolic
24 (600)
1. Mounting closer to the tank wall may be allowed if reduced accuracy is accepted.
Table 2-3. Beam Width Angle
Antenna
Beam width
Cone 3 in.
25
°
Cone 4 in./ Process seal 4 in.
21
°
Cone 6 in./ Process seal 6 in.
18
°
Cone 8 in.
15
°
Parabolic
10
°