40
Reference Manual
00809-0100-4024, Rev CA
Mechanical Installation
March 2020
Mechanical Installation
3. To minimize the influence of disturbing echoes from inlet and outlet pipes you may need to rotate
the transmitter head 90°.
Figure 2-30. Example of Rotating the Transmitter Head to Minimize Disturbing Echoes
2.9
Mounting the parabolic antenna
Figure 2-31. Parabolic Antenna Dimensions
2.9.1
Mounting the flange ball
1. The flange should be between 0.24 and 1.18 in. (6 and 30 mm) thick. Make sure the diameter of the
hole is 3.78 in. (96 mm).
90˚
90˚
Cover lock
7.87 (200)
18.11 (460)
6.4 (162)
17.36 (441)
Dimensions are in inches (millimeters)