Product Certifications
113
Product Certifications
March 2020
Reference Manual
00809-0100-4024, Rev CA
2210 Display Unit
Certificate: IECEx SIR 05.0021X
Standards: IEC 60079-0:2011, IEC 60079-11:2011
Markings: Ex ib llC T4 Gb (Ta = -40 °C to +70 °C) - Without TP40
Temperature Panel or Ex ib [ia Ga] llC T4 Gb (Ta = 40
°C to +70 °C) - With TP40 Temperature Panel
WARNING- POTENTIAL ELECTROSTATIC CHARGING
HAZARD-SEE INSTRUCTIONS
Specific Conditions for Safe Use (X):
1. At Connector X12, Ci is considered to be 22 nF with an
associated apparatus Uo of 6.5 V or 15.7 μF with an
associated apparatus Uo of less than 6.5 V.
2. Under certain extreme circumstances, exposed plastic and
unearthed metal parts of the enclosure may store an
ignition-capable level of electrostatic charge. Therefore, the
user/installer shall implement precautions to prevent the
build-up of electrostatic charge, e.g. locate the equipment
where a charge-generating mechanism is unlikely to be
present and clean with a damp cloth.
* Ci = 22 nF with an associated apparatus U
o
of 6.5 V or greater
Ci = 15.7
μ
F with an associated apparatus U
o
of less than 6.5 V
When the TP40 Temperature panel is fitted, the combined output
parameters are:
The capacitance and either the inductance or the inductance to
resistance (L/R) ratio of the cable connected to the connectors X17
and X18 must not exceed the following values:
B.9 Brazil
E2 INMETRO Flameproof
5600 Series Transmitter
Certificate: UL-BR 18.0034X
Standards: ABNT NBR IEC 60079-0:2013;
ABNT IEC 60079-1:2016; ABNT IEC 60079-7:2008;
ABNT IEC 60079-11:2013;
ABNT IEC 60079-26:2016;
ABNT NBR IEC 60079-31:2014
Markings: Ex db eb IIC T6 Ga/Gb (-40°C ≤ Tamb ≤ +70°C)
Ex db eb [ib] [ia] IIC T6 Gb/Ga
(-40°C ≤ Tamb ≤ +70°C)
Ex db eb [ia] IIC T6 Gb/Ga (-40°C ≤ Tamb ≤ +70°C)
Ex tb IIIC T85°C Db IP65
Specific Conditions for Safe Use (X):
1. See certificate for Specific Conditions.
2210 Display Unit
Certificate: UL-BR 18.0026X
Standards: ABNT NBR IEC 60079-0:2013 e ABNT NBR IEC
60079-11:2013
Markings: Ex ib IIC T4 Gb (Ta = -40 °C à +70 °C) (sem painel
TP40), Ex ib [ia Ga] IIC T4 Gb (Ta = -40 °C à +70 °C)
(com painel TP40)
Specific Conditions for Safe Use (X):
1. See certificate for Specific Conditions.
See certificate for entity parameters
U
o
I
o
P
o
C
o
L
o
Active Analog
Circuit Entity
parameters
23.1 V
125.7 mA 0.726 W
0.14
μ
F
2.2
m
H
U
o
I
o
P
o
C
o
L
o
Output Entity
parameters
7.84 V
385.6 mA 0.678 W
9.3
μ
F
239
μ
H
U
i
I
i
P
i
C
i
L
i
Input Entity
parameters,
Connector X12
12 V
400 mA
0.7 W
22
n
F*
0
μ
H
U
o
I
o
P
o
C
i
L
i
Output Entity
parameters,
Connectors
X17, X18
5.88 V
172.4 mA 0.253 W
0 F
0 H
Group
Capacitance in
mF
Inductance in
mH
or L/R Ratio in
mH/Ω
IIC
43
0.7
140
IIB
1000
5.2
560
IIA
1000
10.0
1120
U
i
I
i
P
i
C
i
L
i
Entity
parameters
HART
30 V
200 mA
0 W
0
μ
F
0
μ
H
Summary of Contents for Rosemount 5600 Series
Page 2: ......
Page 4: ...4 Reference Manual 00809 0100 4024 Rev CA Title Page March 2020 Title Page ...
Page 16: ...16 Reference Manual 00809 0100 4024 Rev CA Introduction March 2020 Introduction ...
Page 125: ...125 Reference Manual 00809 0100 4024 Rev CA Index March 2020 Index Strapping Table 71 ...
Page 126: ...126 Reference Manual 00809 0100 4024 Rev CA Index March 2020 Index ...
Page 127: ......