8.7
Configuring events
An
event
occurs if the real-time value of a user-specified process variable varies above or below a
user-specified value, or inside or outside a user-specified range.
Events can be used to initiate specific transmitter actions. Possible actions include:
•
Start zero
•
Reset mass total
•
Reset volume total
•
Reset gas standard volume total
•
Reset all totalizers
•
Start/stop all totalizers
Up to five events can be configured. You can define more than one event on a single process variable
if desired.
You can configure an event to initiate multiple actions, e.g., you can configure Event 1 to reset both
the mass total and the volume total.
Table 8-4
Effect of flow direction on frequency output, discrete output, totalizers, and digital
communications
Flow direction value
Forward flow
(1)
(1) Process fluid flowing in same direction as flow direction arrow on sensor.
Frequency
output
Discrete output
(2)
(2) Applies only if the discrete output has been configured to indicate flow direction. See Section 6.7.2.
Flow totals
Flow values via
digital comm.
Forward only
Increase
Forward
Increase
Positive
Reverse only
0 Hz
Forward
No change
Positive
Bidirectional
Increase
Forward
Increase
Positive
Absolute value
Increase
Forward
Increase
Positive
(3)
(3) Refer to the digital communications status bits for an indication of whether flow is positive or negative.
Negate/Forward
Zero
Reverse
No change
Negative
Negate/Bidirectional
Increase
Reverse
Decrease
Negative
Flow direction value
Zero flow
Frequency
output
Discrete output
Flow totals
Flow values via
digital comm.
All
0 Hz
Reverse
No change
0
Flow direction value
Reverse flow
(4)
(4) Process fluid flowing in opposite direction from flow direction arrow on sensor.
Frequency
output
Discrete output
Flow totals
Flow values via
digital comm.
Forward only
0 Hz
Reverse
No change
Negative
Reverse only
Increase
Reverse
Increase
Negative
Bidirectional
Increase
Reverse
Decrease
Negative
Absolute value
Increase
Forward
Increase
Positive
Negate/Forward
Increase
Forward
Increase
Positive
Negate/Bidirectional
Increase
Forward
Increase
Positive
Summary of Contents for Micro-Motion 2400S
Page 8: ...vi Micro Motion Model 2400S Transmitters with Analog Outputs ...
Page 20: ...12 Micro Motion Model 2400S Transmitters with Analog Outputs ...
Page 30: ...22 Micro Motion Model 2400S Transmitters with Analog Outputs ...
Page 42: ...34 Micro Motion Model 2400S Transmitters with Analog Outputs ...
Page 66: ...58 Micro Motion Model 2400S Transmitters with Analog Outputs ...
Page 76: ...68 Micro Motion Model 2400S Transmitters with Analog Outputs ...
Page 138: ...130 Micro Motion Model 2400S Transmitters with Analog Outputs ...
Page 190: ...182 Micro Motion Model 2400S Transmitters with Analog Outputs ...
Page 197: ......