Configuration and Use Manual
97
Pressure Compensation, Temperature Compensation, and Polling
Meas
ure
m
ent P
e
rf
ormance
Defaults
T
rou
b
le
s
ho
oti
n
g
Compensa
tion
Figure 9-2
Configuring pressure compensation with the Communicator
9.3
External temperature compensation
External temperature compensation can be used with the petroleum measurement application or the
enhanced density application.
There are two ways to configure external temperature compensation:
•
If the operating temperature is a known static value, you can enter the operating temperature in
the software, and not poll a temperature measurement device.
•
If the operating temperature varies significantly, you configure the transmitter to poll for an
updated temperature value from an external temperature measurement device. Polling requires
HART/Bell 202 communications over the mA output.
Note: If you configure a static temperature value, ensure that it is accurate. If you configure polling
for temperature, ensure that the external temperature measurement device is accurate and reliable.
To enable and configure external temperature compensation:
•
With ProLink II, see Figure 9-3.
•
With the Communicator, see Figure 9-4.
Enter
Flow fctr
Configure pressure compensation
Enter
Dens fctr
Enter
Flowcal pressure
Go to
Polling
Setup
(2)
Disable polling for
pressure
(3)
Enter
Static
Pressure
Poll?
Static?
Done
6 Pressure Comp
2 Config field dev var
Enter
Pressure unit
Set pressure measurement unit
(1)
4 Pressure
Send
Home
Send
Home
Send
Home
1 Charize Sensor
Enable pressure comp
On-Line Menu >
5 Detailed Setup
On-Line Menu >
5 Detailed Setup
(1) Pressure measurement unit must be configured to
match pressure unit used by external device. See
Section 6.4.
(2) See Section 9.4.
(3) If previously configured. Polling for temperature is
allowed. See Section 9.4.
Summary of Contents for Micro-Motion 2400S
Page 8: ...vi Micro Motion Model 2400S Transmitters with Analog Outputs ...
Page 20: ...12 Micro Motion Model 2400S Transmitters with Analog Outputs ...
Page 30: ...22 Micro Motion Model 2400S Transmitters with Analog Outputs ...
Page 42: ...34 Micro Motion Model 2400S Transmitters with Analog Outputs ...
Page 66: ...58 Micro Motion Model 2400S Transmitters with Analog Outputs ...
Page 76: ...68 Micro Motion Model 2400S Transmitters with Analog Outputs ...
Page 138: ...130 Micro Motion Model 2400S Transmitters with Analog Outputs ...
Page 190: ...182 Micro Motion Model 2400S Transmitters with Analog Outputs ...
Page 197: ......