Parameter description
protocol
Performance
Menu
7
The
following
modes
are
available
for
the
analog
inputs
2
and
3.
Modes
7,
8
and
9
are
only
available
with
analog
input
3.
Parameter
structure
Keypad
and
format
Advanced
parameter
descriptions
Serial
comms
In
modes
2
and
3
a
current
loop
loss
trip
is
generated
if
the
input
current
falls
below
3
mA.
In
modes
4
and
5
the
analog
input
level
goes
to
0.0
%
if
the
input
current
falls
below
3
mA.
Mentor
MP
Advanced
User
Guide
111
Issue
Number:
4
www.onxcontrol.com
Parameter
value
Parameter
string
Mode
Comments
0
0-20
0
-
20
mA
1
20-0
20
-
0
mA
2
4-20.tr
4
-
20
mA
with
trip
on
loss
Trip
if
I
<
3
mA
3
20-4.tr
20
-
4
mA
with
trip
on
loss
Trip
if
I
<
3
mA
4
4-20
4
-
20
mA
with
no
trip
on
loss
5
20-4
20
-
4
mA
with
no
trip
on
loss
6
VOLt
Voltage
mode
7
th.SC
Thermistor
with
short
circuit
detection
TH
trip
if
R
>
3
k
3
TH
reset
if
R
<
1
k
8
THS
trip
if
R
<
50
R
8
th
Thermistor
without
short
circuit
detection
TH
trip
if
R
>
3
k
3
TH
reset
if
R
<
1
k
8
9
th
diSp
Thermistor
display
only
with
no
trip
7.08
T5/6
analog
input
1
scaling
Coding
Bit
SP
FI
DE
TE
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
3
1
1
1
Range
0.000
to
40.000
Default
1.000
Update
rate
Background
read
7.10
T5/6
analog
input
1
destination
Coding
Bit
SP
FI
DE
TE
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
2
1
1
1
1
Range
Pr
0.00
to
Pr
22.99
Default
Pr
1.36
Update
rate
Read
on
drive
reset
7.11
T7
analog
input
2
mode
Coding
Bit
SP
FI
DE
TE
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
1
1
Range
0
to
6
Default
6
Update
rate
Background
read
7.09
T5/6
analog
input
1
invert
Coding
Bit
SP
FI
DE
TE
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
1
Default
0
Update
rate
Background
read
MP700A6(R)
100
95
90
MP825A6(R)
94
90
85
MP1200A6(R)
110
100
95
MP1850A6(R)