Table 4-56. Analog Input Block Parameter Definitions
Label
PARAMETER_NAME
Description
Initial
Value
Range
Write Block
Mode
RO /
RW
Index
Number
Block Alarm
BLOCK_ALM
21
Data Type: DS-72
The block alarm is used for all configuration,
hardware, connection failure or system problems
in the block. The cause of the alert is entered in
the subcode field.
UNACKNOWLEDGED
21.1
RW
0
=
Undefined
1
=
Acknowledged
2
=
Unacknowledged
ALARM_STATE
21.2
RO
0
=
Undefined
1
=
Clear-reported
2
=
Clear-not reported
3
=
Active-reported
4
=
Active-not reported
TIME_STAMP
21.3
RO
SUBCODE
21.4
RO
VALUE
21.5
RO
Alarm Summary
ALARM_SUM
22
Data Type: DS-74 Current alert status,
unacknowledged states, unreported states, and
disabled states of the alarms associated with the
function block.
0=clear
0=acknowledged
0=reported
0=enabled
CURRENT
22.1
RO
ALL
0: Discrete alarm
1: Hi Hi alarm
2: Hi Alarm
3: Lo Lo Alarm
4: Lo Alarm
7: Block alarm
UNACKNOWLEDGED
22.2
RO
ALL
UNREPORTED
22.3
RO
ALL
D ISABLED
22.4
RW
ALL
All bits: 0
Acknowledge Option
ACK_OPTION
23
ALL
0: Discrete alarm
1: Hi Hi alarm
2: Hi Alarm
3: Lo Lo Alarm
4: Lo Alarm
7: Block alarm
All bits: 0
Data Type: Bit String
0
=
Disable
1
=
Enable
Selection of whether alarms associated with the
block will be automatically acknowledged.
Alarm Hysteresis
ALARM_HYS
24
ALL
0
−
50%
0.50%
Data Type: Float
Hysteresis on alarms.
High High Priority
HI_HI_PRI
25
ALL
0 to 15
0
Data Type: Unsigned8
The priority of the hi hi alarm.
High High Limit
HI_HI_LIM
26
ALL
OUT_SCALE
0
Data Type: Float
Value of analog input which will generate an alarm.
High Priority
HI_PRI
27
ALL
0 to 15
0
Data Type: Unsigned8
The priority of the high alarm.
Hi Limit
HI_LIM
28
ALL
OUT_SCALE
0
Data Type: Float
Value of analog input which will generate an alarm.
Low Priority
LO_PRI
29
ALL
0 to 15
0
Data Type: Unsigned8
The priority of the low alarm.
Low Limit
LO_LIM
30
ALL
OUT_SCALE
0
Data Type: Float
Value of analog input which will generate an alarm.
Low Low Priority
LO_LO_PRI
31
ALL
0 to 15
0
Data Type: Unsigned8
The priority of the low low alarm.
Low Low Limit
LO_LO_LIM
32
ALL
OUT_SCALE
0
Data Type: Float
Value of analog input which will generate an alarm.
High High Alarm
HI_HI_ALM
33
Data Type: DS-71
The status of the hi hi alarm and its associated
time stamp.
UNACKNOWLEDGED
33.1
RW
N/A
0
ALARM_STATE
33.2
RO
0
TIME_STAMP
33.3
RO
0
SUBCODE
33.4
RO
0
VALUE
33.5
RO
0
High Alarm
HI_ALM
34
Data Type: DS-71
The status of the hi alarm and its associated time
stamp.
UNACKNOWLEDGED
34.1
RW
N/A
0
ALARM_STATE
34.2
RO
0
TIME_STAMP
34.3
RO
0
SUBCODE
34.4
RO
0
VALUE
34.5
RO
0
−
Continued
−
4
Summary of Contents for Fisher FIELDVUE DVC6000f
Page 54: ...DVC6000f Digital Valve Controllers December 2009 2 30 2 ...
Page 62: ...DVC6000f Digital Valve Controllers December 2009 4 2 4 ...
Page 127: ...Transducer Block December 2009 4 67 4 ...
Page 141: ...AO Function Block December 2009 4 81 4 ...
Page 207: ...MAI Function Block December 2009 4 147 4 ...
Page 219: ...DO Function Block December 2009 4 159 4 ...
Page 231: ...DI Function Block December 2009 4 171 4 ...
Page 302: ...DVC6000f Digital Valve Controllers December 2009 8 16 8 ...
Page 306: ...DVC6000f Digital Valve Controllers December 2009 A 4 A ...
Page 350: ...DVC6000f Digital Valve Controllers December 2009 E 6 E ...
Page 368: ...DVC6000f Digital Valve Controllers December 2009 F 18 F ...
Page 372: ...DVC6000f Digital Valve Controllers December 2009 Glossary 4 Notes G Glossary ...
Page 382: ...DVC6000f Digital Valve Controllers December 2009 Index 10 F Index ...