![Emerson Fisher FIELDVUE DVC6000f Instruction Manual Download Page 11](http://html.mh-extra.com/html/emerson/fisher-fieldvue-dvc6000f/fisher-fieldvue-dvc6000f_instruction-manual_102337011.webp)
x
x
Resource Block (RB) Menu Structure
PARAMETER LABEL
MENU STRUCTURE
Alert Key
RB
>
Configure/Setup
>
Alarm Handling
>
Alert Key
Block Alarm: Alarm State
RB
>
Device Diagnostics
>
Block Alarm
>
Block Alarm: Alarm State
Block Alarm: Unacknowledged
RB
>
Device Diagnostics
>
Block Alarm
>
Block Alarm: Unacknowledge
Block Alarm Disabled
RB
>
Configure/Setup
>
Alarm Handling
>
Alarm Summary:Disabled.Block Alarm Disabled
Block Alarm Automatically
Acknowledge
RB
>
Configure/Setup
>
Alarm Handling
>
Acknowledge Option.Block Alarm Automatically Acknowledge
Confirm Time
RB
>
Configure/Setup
>
Alarm Handling
>
Confirm Time
DD Information
RB
>
Device Variables
>
DD information
Device ID
RB
>
Configure/Setup
>
Identification
>
Device ID or RB
>
Device Variables
>
Instrument
>
Identification
>
Device ID
Device Revision
RB
>
Configure/Setup
>
Version
>
Device Revision or RB
>
Device Variables
>
Instrument
>
Version
>
Device Revision
Device State
RB
>
Display
>
Resource Status
>
Device State
RB
>
Device Diagnostics
>
Device State
Device Type
RB
>
Configure/Setup
>
Identification
>
Device Type or RB
>
Device Variables
>
Instrument
>
Identification
>
Device Type
Diagnostics Options
RB
>
Configure/Setup
>
Options
>
Diagnostics Options
Discrete Alarm Disabled
RB
>
Configure/Setup
>
Alarm Handling
>
Alarm Summary:Disabled.Discrete Alarm Disabled
Discrete Alarm Automatically
Acknowledge
RB
>
Configure/Setup
>
Alarm Handling
>
Acknowledge Option.Discrete Alarm Automatically Acknowledge
Electronics Serial Number
RB
>
Configure/Setup
>
Identification
>
Elect S/N or RB
>
Device Variables
>
Instrument
>
Identification
>
Electronics Serial
Number
Factory Serial Number
RB
>
Configure/Setup
>
Identification
>
Factory S/N or RB
>
Device Variables
>
Instrument
>
Identification
>
Factory Serial
Number
Fault State
RB
>
Device Diagnostics
>
Maintenance
>
Fault State
Features Available
RB
>
Configure/Setup
>
Options
>
Features Available or RB
>
Device Variables
>
Options
>
Features Available
Features Selected
RB
>
Configure/Setup
>
Options
>
Features Selected
Field Serial Number
RB
>
Configure/Setup
>
Identification
>
Field S/N or RB
>
Device Variables
>
Instrument
>
Identification
>
Field Serial Number
Firmware Revision
RB
>
Configure/Setup
>
Version
>
Firmware Revision or RB
>
Device Variables
>
Instrument
>
Version
>
Firmware Revision
Function Block Options
RB
>
Configure/Setup
>
Options
>
Function Block Options or RB
>
Device Variables
>
Options
>
Function Block Options
Hardware Revision
RB
>
Configure/Setup
>
Version
>
Hardware Revision or RB
>
Device Variables
>
Instrument
>
Version
>
Hardware Revision
ITK Version
RB
>
Configure/Setup
>
Version
>
ITK Version or RB
>
Device Variables
>
Instrument
>
Version
>
ITK Version
Limit Notify
RB
>
Configure/Setup
>
Alarm Handling
>
Limit Notify
Manufacturer
RB
>
Configure/Setup
>
Identification
>
Manufacturer or RB
>
Device Variables
>
Instrument
>
Identification
>
Manufacturer
Maximum Notify
RB
>
Configure/Setup
>
Alarm Handling
>
Maximum Notify
Miscellaneous Options
RB
>
Configure/Setup
>
Options
>
Miscellaneous Options or RB
>
Device Variables
>
Options
>
Miscellaneous Options
Resource Block Error
RB
>
Device Diagnostics
>
Resource
Block Error
Shed Remote Cascade
RB
>
Configure/Setup
>
Communication Time Out
>
Shed Remote Cascade
Shed Remote Out
RB
>
Configure/Setup
>
Communication Time Out
>
Shed Remote Out
Standby Firmware Revision
RB
>
Configure/Setup
>
Version
>
Standby Software Revision or RB
>
Device Variables
>
Instrument
>
Version
>
Standby
Software Revision
Strategy
RB
>
Configure/Setup
>
Identification
>
Strategy or RB
>
Device Variables
>
Instrument
>
Identification
>
Strategy
Tag Description
RB
>
Configure/Setup
>
Identification
>
Tag Description or RB
>
Device Variables
>
Instrument
>
Identification
>
Tag Description
Write Alarm: Alarm State
RB
>
Device Diagnostics
>
Write Lock
>
Write Alarm: Alarm State
Write Lock
RB
>
Configure/Setup
>
Write Lock
>
Write Lock or RB
>
Device Diagnostics
>
Write Lock
>
Write Lock
Write Priority
RB
>
Configure/Setup
>
Write Lock
>
Write Priority
Summary of Contents for Fisher FIELDVUE DVC6000f
Page 54: ...DVC6000f Digital Valve Controllers December 2009 2 30 2 ...
Page 62: ...DVC6000f Digital Valve Controllers December 2009 4 2 4 ...
Page 127: ...Transducer Block December 2009 4 67 4 ...
Page 141: ...AO Function Block December 2009 4 81 4 ...
Page 207: ...MAI Function Block December 2009 4 147 4 ...
Page 219: ...DO Function Block December 2009 4 159 4 ...
Page 231: ...DI Function Block December 2009 4 171 4 ...
Page 302: ...DVC6000f Digital Valve Controllers December 2009 8 16 8 ...
Page 306: ...DVC6000f Digital Valve Controllers December 2009 A 4 A ...
Page 350: ...DVC6000f Digital Valve Controllers December 2009 E 6 E ...
Page 368: ...DVC6000f Digital Valve Controllers December 2009 F 18 F ...
Page 372: ...DVC6000f Digital Valve Controllers December 2009 Glossary 4 Notes G Glossary ...
Page 382: ...DVC6000f Digital Valve Controllers December 2009 Index 10 F Index ...