DVC6000f Digital Valve Controllers
December 2009
4-134
AI Block Parameter List
Read/Write Capability: RO
−
Read Only, RW
−
Read Write
Mode: The block mode(s) required to write to the parameter
Double indentation and shaded Index Number indicates sub-parameter
Table 4-56. Analog Input Block Parameter Definitions
Label
PARAMETER_NAME
Index
Number
RO /
RW
Write Block
Mode
Range
Initial
Value
Description
Static Revision
ST_REV
1
RO
N/A
0 to 65535
0
Data Type: Unsigned16
The revision level of the static data associated
with the function block. The revision value will be
incremented each time a static parameter value in
the block is changed
Tag Description
TAG_DESC
2
ALL
7 bit ASCII
spaces
Data Type: Octet String
The user description of the intended application of
the block.
Strategy
STRATEGY
3
ALL
0 to 65535
0
Data Type: Unsigned16
The strategy field can be used to identify grouping
of blocks. This data is not checked or processed
by the block.
Alert Key
ALERT_KEY
4
ALL
1 to 255
0
Data Type: Unsigned8
The identification number of the plant unit. This
information may be used in the host for sorting
alarms, etc.
Block Mode
MODE_BLK
5
Data Type: DS-69
Valid Bits: 7: OOS, 4: MAN, 3: AUTO
The actual, target, permitted, and normal modes of
the block.
Target: The requested block mode
Actual: The current mode of the block
Permitted: Allowed modes for Target
Normal: Most common mode for Target
TARGET
5.1
RW
ALL
OOS
MAN
AUTO
OOS until block
is configured,
then last valid
target
ACTUAL
5.2
RO
ALL
OOS
PERMITTED
5.3
RW
ALL
OOS+MAN+AUTO
OOS, MAN,
AUTO
NORMAL
5.4
RW
ALL
AUTO
Block Error
BLOCK_ERR
6
RO
1: Block Configuration
Error
3: Simulate Active
7: Input Failure/ Bad
PV Status
14: Power-up
15: Out-of-Service
Data Type: Bit String
0
=
Inactive
1
=
Active
Error status associated with the hardware or
software for the AI block.
Process Value
PV
7
RO
PV Status set equal to
FIELDV_VAL Status
Data Type: DS-65
Reflects the scaled value from the configured
channel. Units set by OUT_SCALE and L_TYPE.
Primary Output
OUT
8
OOS, MAN
OUT_STATE
Data Type: DS-68
The block output value and status.
Simulate
SIMULATE
9
Data Type: DS-82
A group of data that contains the current
transducer value and status, the simulated
transducer value and status, and the
enable/disable bit.
SIMULATE_STATUS
9.1
ALL
0
SIMULATE_VALUE
9.2
ALL
0
TRANSDUCER_STATUS
9.3
RO
0
TRANSDUCER_VALUE
9.4
RO
0
ENABLE/DISABLE
9.5
ALL
0=Not Initialized
1=Simulation Disabled
2=Simulation Active
1=simulate
disabled
Transducer Scale
XD_SCALE
10
OOS
EU at 100%
EU at 10%
Units Index
Decimal Point
100
0
%
2
Data Type: DS-68
Transducer scaling (XD_SCALE) is applied to the
value from the channel to produce the FIELD_VAL
in percent. The XD_SCALE units code must match
the channel units code (if one exists), or the block
will remain in OOS mode after being configured.
−
Continued
−
4
Summary of Contents for Fisher FIELDVUE DVC6000f
Page 54: ...DVC6000f Digital Valve Controllers December 2009 2 30 2 ...
Page 62: ...DVC6000f Digital Valve Controllers December 2009 4 2 4 ...
Page 127: ...Transducer Block December 2009 4 67 4 ...
Page 141: ...AO Function Block December 2009 4 81 4 ...
Page 207: ...MAI Function Block December 2009 4 147 4 ...
Page 219: ...DO Function Block December 2009 4 159 4 ...
Page 231: ...DI Function Block December 2009 4 171 4 ...
Page 302: ...DVC6000f Digital Valve Controllers December 2009 8 16 8 ...
Page 306: ...DVC6000f Digital Valve Controllers December 2009 A 4 A ...
Page 350: ...DVC6000f Digital Valve Controllers December 2009 E 6 E ...
Page 368: ...DVC6000f Digital Valve Controllers December 2009 F 18 F ...
Page 372: ...DVC6000f Digital Valve Controllers December 2009 Glossary 4 Notes G Glossary ...
Page 382: ...DVC6000f Digital Valve Controllers December 2009 Index 10 F Index ...