Digitax ST User Guide
193
Issue: 5
SLX.Er
Solutions Module slot X trip: Solutions Module in slot X or Digitax ST EZMotion has detected a fault
202,207,212
Automation (EZMotion) module category
Check value in Pr
17.50
. The following table lists the possible error codes for the Digitax ST EZMotion. See the
Advanced parameter
section in the Digitax ST Advanced User Guide for more information.
Trip
Diagnosis
Error Code
Trip Description
41
Digitax ST parameter access error - Parameter does not exist
42
Digitax ST parameter access error - Parameter is read-only
43
Digitax ST parameter access error - Parameter is write-only
44
Digitax ST parameter access error - Written value out of range
73
Digitax ST database set-up error
74
Module overheat error
101
Invalid configuration error
102
NVM invalid error
103
Power up test failure error
104
Following error
105
Travel limit plus
106
Travel limit minus
107
No program error
108
Motion trajectory error
109
Trajectory update overrun error
120
File corruption error - Consult factory
121
122
123
Program error - Buffer overrun
124
Program error - Call stack overflow
125
File corruption error - Consult factory
126
127
Flash error
128
File corruption error - Consult factory
129
Program error - illegal command
130
File corruption error - Consult factory
131
132
133
134
135
Program error - Math addition overflow
136
Program error - Math divide by zero
137
Program error - Math divide operand too large
138
Program error - Math multiplication normalization failed
139
Program error - Math divide operand too large
140
Program error - Overflow
141
Program error - Math subtraction overflow
142
Program error - Math stack overflow
143
File corruption error - Consult factory
144
145
146
147
Program error - Flash memory size exceeded
148
Program error - RAM memory size exceeded
153
File corruption error - Consult factory
154
155
156
Program error - Too many wait for instructions
157
File corruption error - Consult factory
158
159
160
161
162
163
164
165
166
Program error - EZMotion parameter write out of range
171
Invalid slot 1 selection
172
Invalid slot 2 selection
173
Invalid motion processor
174
File corruption error - Consult factory
175
Module output overload
Summary of Contents for Digitax ST