Digitax ST User Guide
163
Issue Number: 5
12.17 Menu 18: Application menu 1
12.18 Menu 19: Application menu 2
12.19 Menu 20: Application menu 3
Menu 20 parameters are transferred to the SMARTCARD when a 4yyy transfer is performed. See section 10.2.1
page 102 for more information.
Parameter
Range(
Ú
)
Default(
Ö
)
Type
18.01
Application menu 1 power-down
saved integer
-32,768 to +32,767
0
RW Bi
NC
PS
18.02 to
18.10
Application menu 1 read-only integer
-32,768 to +32,767
0
RO Bi
NC
18.11 to
18.30
Application menu 1 read-write integer
-32,768 to +32,767
0
RW Bi
US
18.31 to
18.50
Application menu 1 read-write bit
OFF (0) or On (1)
0
RW Bit
US
Parameter
Range(
Ú
)
Default(
Ö
)
Type
19.01
Application menu 2 power-down
saved integer
-32,768 to +32,767
0
RW Bi
NC
PS
19.02 to
19.10
Application menu 2 read-only integer
-32,768 to +32,767
0
RO Bi
NC
19.11 to
19.30
Application menu 2 read-write integer
-32,768 to +32,767
0
RW Bi
US
19.31 to
19.50
Application menu 2 read-write bit
OFF (0) or On (1)
0
RW Bit
US
Parameter
Range(
Ú
)
Default(
Ö
)
Type
20.01 to
20.20
Application menu 3 read-write integer
-32,768 to +32,767
0
RW Bi
NC
20.21 to
20.40
Application menu 3 read-write long
integer
-2
31
to 2
31
-1
0
RW Bi
NC
RW Read / Write
RO
Read only
Uni
Unipolar
Bi
Bi-polar
Bit
Bit parameter
Txt
Text string
FI
Filtered
DE
Destination
NC
Not copied
RA
Rating dependent
PT
Protected
US
User save
PS
Power down save