Digitax ST User Guide
187
Issue: 5
Et
External trip from input on terminal 31
6
Check terminal 31 signal
Check value of Pr
10.32
Enter 12001 in Pr
xx.00
and check for parameter controlling Pr
10.32
Ensure Pr
10.32
or Pr
10.38
(=6) are not being controlled by serial comms
HF01
Data processing error: CPU address error
Hardware fault - return drive to supplier
HF02
Data processing error: DMAC address error
Hardware fault - return drive to supplier
HF03
Data processing error: Illegal instruction
Hardware fault - return drive to supplier
HF04
Data processing error: Illegal slot instruction
Hardware fault - return drive to supplier
HF05
Data processing error: Undefined exception
Hardware fault - return drive to supplier
HF06
Data processing error: Reserved exception
Hardware fault - return drive to supplier
HF07
Data processing error: Watchdog failure
Hardware fault - return drive to supplier
HF08
Data processing error: Level 4 crash
Hardware fault - return drive to supplier
HF09
Data processing error: Heap overflow
Hardware fault - return drive to supplier
HF10
Data processing error: Router error
Hardware fault - return drive to supplier
HF11
Data processing error: Access to EEPROM failed
Hardware fault - return drive to supplier
HF12
Data processing error: Main program stack overflow
Hardware fault - return drive to supplier
HF13
Data processing error: Software incompatible with hardware
Hardware or software fault - return drive to supplier
HF17
Multi-module system thermistor short circuit or open circuit
217
Hardware fault - return drive to supplier
HF18
Multi-module system interconnect cable error
218
Hardware fault - return drive to supplier
HF19
Temperature feedback multiplexing failure
219
Hardware fault - return drive to supplier
HF20
Power stage recognition: serial code error
220
Hardware fault - return drive to supplier
HF21
Power stage recognition: unrecognized frame size
221
Hardware fault - return drive to supplier
HF22
Power stage recognition: multi module frame size mismatch
222
Hardware fault - return drive to supplier
HF23
Power stage recognition: multi module voltage rating mismatch
223
Hardware fault - return drive to supplier
HF24
Power stage recognition: unrecognized drive size
224
Hardware fault - return drive to supplier
Trip
Diagnosis
Summary of Contents for Digitax ST
Page 1: ...User Guide AC variable speed drive for servo motors Part Number 0475 0001 05 Issue 5 ...
Page 209: ......