3410 Series Gas Ultrasonic Meters Operations Manual
Section 7: Tools commands
3-9000-777 Rev D
June 2016
Upgrade program components
135
7.7
Upgrade program components
Use the Daniel MeterLink
Tools|Program Download
dialog to upgrade the program components
in Daniel Ultrasonic meter. When the dialog is first opened, the Currently Installed Versions table
will show the currently installed program components in the meter.
The firmware to download to a meter is available as a compressed file with a.zip extension.
Daniel MeterLink unzips the file when it is opened.
Figure 7-8 Program download dialog
1.
Click
Open
to display an Open Download File dialog and select the desired file and click
Open
.
The filename displays in the
File
edit box under
Upgrade
. The Version and Date of the
components to download display in the table under
Upgrade
. All of the components will
be identified as if they are older, newer, or the same as what is currently installed in the
meter.
2.
Daniel MeterLink only downloads components that are different than what is currently
installed in the meter. At least one component must be different for download before
the
Download
button is enabled.
3.
Click
Download
to initiate the download process. Daniel MeterLink collects the
configuration from the meter and displays a message where it was saved. If the upgrade
requires the database to be reset, then it will be necessary to use the
Edit/Compare
Configuration
dialog to write this configuration back down to the meter after the
program download is complete (
see Section 7.1
). After the configuration is saved, a
progress bar will appear showing the status of the file download. After the files have
been transferred successfully to the meter, the meter will start the upgrade process and
the status will be shown down below
Upgrade Progress
.