FRU Installation
AXP640 Installation and Use (6806800M24E)
129
Removal Procedure
To remove a PEM, refer to this figure and follow the steps.
1. Remove the front bezel by squeezing the retention clasps incorporated into the top
corners of the bezel, and rotating the top of the bezel away from the chassis.
2. Locate the target power input cable’s terminals at the branch circuit or power
distribution unit. Open the external circuit breakers that provide DC feed power to
the PEM you are replacing.
3. Lock and tagout the circuit breakers on the branch circuit or power distribution
unit.
4. Using the appropriate tool, loosen the chassis retention screw on the top of the
PEM.
5. Open the circuit breaker on the PEM module being removed.