FRU Installation
AXP640 Installation and Use (6806800M24E
)
128
Replacing one PEM is done while the other PEM is in operation. Having the PEM located in the
shelf is critical to maintaining proper airflow and cooling of the shelf. Steps in which a PEM is
removed from a slot and reinserted should be completed within 3 minutes to maintain the
shelf within safe operating temperatures.
Read all cautions and warnings, and ensure the equipment is properly grounded by
reviewing the procedure in
, and follow these steps. The PEM
has multiple power sources. This procedure should be followed precisely to ensure the PEM
is isolated from all power sources before removing the PEM from the shelf.
This procedure assumes that the redundant PEMs are powered on in the shelf.