Site Preparation
AXP640 Installation and Use (6806800M24E
)
56
3.2.3.1
Environmental Requirements
To ensure proper function of the system, make sure that the environment in which the system
is to be used fulfills the environmental requirements.
The environmental values must be tested and proven in the planned system configuration,
that is, the delivered system and other third-party products you want to integrate.
The following table lists the environmental requirements.
z
Operating temperatures refer to the temperature of the air circulating at the air intake of
the system and not to component temperatures.
z
Some of the climatic values may exceed the specification of some system components
(for example, hard disks). As Emerson cannot guarantee the functionality of third party
products that are handled or operated out of their specifications, the environmental
conditions may be limited to the specifications of these components.
Table 3-1 Environmental Conditions
Feature
Operating
Non-Operating (packed state)
Temperature
+5ºC (41°F) to +40ºC (104°F) (normal
operation) according to NEBS standard
GR-63-CORE
-5°C (23°F) to +55°C (131°F) (exceptional
operation) according to NEBS standard
GR-63-CORE
-40°C (-40°F) to +70°C (158°F)
Temp. change
+/-0.25°C/min
according to NEBS standard GR-63-CORE
+/-0.25°C/min
Relative
humidity
5% to 90% non-condensing
according to Emerson-internal
environmental requirements
5% to 95% non-condensing
according to Emerson-internal
environmental requirements
Shock
Half-sine, 11 ms, 30 m/s
2
Blade level packaging
Half-sine, 6 ms at 180 m/s
2
Vibration
(tested in
target
platform)
0.1g from 5 Hz to 100 Hz and back to 5 Hz at
a rate of 0.1 octave/minute
5-20 Hz at 0.01 g
2
/Hz
20-200 Hz at -3.0 dB/octave
Random 5-20 Hz at 1m
2
/s
3
Random 20-200 Hz at -3 dB/octave
Summary of Contents for AXP640-AC2-110VAC
Page 8: ...AXP640 Installation and Use 6806800M24E Contents 8 Contents Contents ...
Page 10: ...AXP640 Installation and Use 6806800M24E 10 List of Tables ...
Page 26: ...Platform Architecture AXP640 Installation and Use 6806800M24E 26 ...
Page 46: ...AXP640 Shelf Description AXP640 Installation and Use 6806800M24E 46 Figure 2 14 AC Inlet 220V ...
Page 52: ...AXP640 Shelf Description AXP640 Installation and Use 6806800M24E 52 ...
Page 76: ...Site Preparation AXP640 Installation and Use 6806800M24E 76 ...
Page 86: ...AXP640 Operations AXP640 Installation and Use 6806800M24E 86 ...
Page 110: ...AXP640 Shelf Installation AXP640 Installation and Use 6806800M24E 110 ...
Page 138: ...FRU Installation AXP640 Installation and Use 6806800M24E 138 ...
Page 189: ......