Home, Sleep and Away Temperature 
Pre-Sets

You can set your (Home, Sleep, Away) temperatures for use 
when you get home, go to sleep, or leave home. Then, just 
press the button you want and go.
Favorite Temperatures are set at the factory as indicated in 
the following table. You can use pre-sets or change to different 
temperature pre-sets.

Factory Pre-set Temperatures

HEATING

COOLING

70

F

75

F

SLEEP

62

F

78

F

62

F

83

F

Your Pre-set Temperatures

HEATING

COOLING

SLEEP

Sleep Timer Option

The sleep timer will automatically change the thermostat from the Sleep to Home temperature after the number of hours set in 
the configuration menu. The Sleep timer default is 8 hours and can be changed to a setting between 1 to 12 hours.
Example: You have selected 8 hours for the Sleep timer in the configuration menu. Press the Sleep button, the thermostat will 
maintain the sleep temperature for 8 hours. After 8 hours the thermostat will go back to the Home temperature. The Sleep timer 
will be activated each time the sleep button is pressed.

Change Filter Reminder Option

The thermostat can display a reminder when it is time to change the air filter on your heating and cooling system. The Change 
Filter will automatically display after the number of hours set in the configuration menu. The change filter reminder time default 
is 200 hours and can be changed to a setting of 25 to 1975 hours; 200 hours is approximately 3 months.
Example: You have selected 250 hours for the change filter reminder. The thermostat will display change filter after 250 it has 
counted down 250 hours. When 

“Change Filter”

 is displayed, press the 

 or 

 button to clear the display and restart the 

timer.

Cool Savings™ Option

With Cool Savings enabled, the thermostat will make small adjustments to the desired temperature during periods of high 
demand to reduce cooling system running time and save energy. When the cooling system has been running for more than 
20 minutes, humidity in the home will be lower and a higher temperature will feel comfortable. After 20 minutes of run time, 
the thermostat will start increasing the desired temperature in steps of less than one degree as the system continues to run. 
These adjustments will eventually cause the system to satisfy the thermostat and turn the system off to reduce the energy 
consumption. When the Cool Savings feature is active and making adjustments, the display will flash “Save”. The amount of 
adjustments to the desired temperature is dependent on the Cool Savings value that is set, 1 being the least adjustment and 6 
being the most adjustment. With this feature set to OFF, no change will occur when the cooling system is continuously running 
during the periods of high demand. Periods of high demand will normally occur during the late afternoon and early evening on 
the hottest days of the summer.

Change Home, Sleep and Away

Temperature Pre-sets

1.  Move SYSTEM switch to 

HEAT

 position. 

2.  Using the 

 or 

 button, set the desired temperature.

3.  Press and hold the 

Home, Sleep,

 or 

Away

 button for 3 

seconds. The display will go blank (except for the battery 
icon and heat/cool icon) and back on again indicating that 
the thermostat has saved your pre-set.

4.  Repeat the process for the remaining Pre-sets to be 

changed.

5.  Move SYSTEM switch to 

COOL

 to Pre-set Temperatures 

for cooling.

Use Home, Sleep and Away Temperature Pre-Sets

1.  Press the 

Home,

 

Sleep,

 or 

Away

 button. The display 

will show the icon for the button pressed and display the 
temperature setting. 

2. The thermostat will maintain the selected pre-set 

temperature until you change it by pressing the 

 or 

 

button or selecting another Pre-set Temperature.

Summary of Contents for 1F89EZ-0251

Page 1: ...NO 37 7208B Replaces 37 7208A 1106 Message to Homeowner Congratulations on choosing the Emerson Blue Easy Set Thermostat The Easy Set is designed to be the easiest thermostat you have ever used This thermostat features Home Sleep and Away temperature pre sets Just press the button and go Included with the easy set is the same temperature accuracy and reliability you expect from all the Emerson Blu...

Page 2: ...ervice indicatesadiagnosticfaultintheheating cooling system It does not indicate a fault in the thermostat 13 indicates power level of batteries Change indicates batteries should be replaced 14 AUX indicates auxiliary stage is operating 15 EMER is displayed flashing when the system switch is in EMER position Batteries Two AA alkaline batteries are included with your thermostat Prior to use open th...

Page 3: ... Savings enabled the thermostat will make small adjustments to the desired temperature during periods of high demand to reduce cooling system running time and save energy When the cooling system has been running for more than 20 minutes humidity in the home will be lower and a higher temperature will feel comfortable After 20 minutes of run time the thermostat will start increasing the desired tem...

Page 4: ...ngeover relay in HEAT the O B switch must be moved to the B position Check Thermostat Operation Heating System 1 Move SYSTEM switch to HEAT position If the heating system has a standing pilot be sure to light it 2 Press to adjust thermostat setting to 1 above room temperature The heating system should begin to operate 3 Press to adjust temperature setting below room temperature The heating system ...

Page 5: ...y is pressed 09 Room Temp 0 4 LO to 4 HI Select room temperature display for 4o higher or 4o lower than the actual temperature 10 o F o C Select o F or o C Display temperature displayed in Fahrenheit or Celsius 11 FH On OFF Select fast second stage On or OFF 12 Change Filter OFF On Select filter maintenance indicator OFF or On If selected OFF item B will be skipped 13 Change Filter 200 h 25 to 197...

Page 6: ...lacement Set System Switch to Cool and lower setpoint below room temperature Verify thermostat and system wires are securely attached Same procedure as diagnostic for No Heat condition except set the thermostat to Cool and lower the setpoint below the room temperature There may be up to a five minute delay before the thermostat clicks in Cooling if the compressor lock out option is selected in the...

Page 7: ...MOSTAT APPLICATION GUIDE Thermostat Configuration Options Thermostat Applications Maximum Stages Heat Cool Heat Pump 1 Single Stage Compressor Heat Pump HP Single Stage Compres sor Heat Pump Systems with Aux Emergency Heat 2 1 Specifications Electrical Rating Battery Power or Hardwire 20 to 30 VAC 50 60 Hz or DC Terminal Load 1 5 A per terminal 2 5 A maximum all terminals combined Setpoint Range 4...

Page 8: ...www white rodgers com www emersonclimate com White Rodgers is a division of Emerson Electric Co The Emerson logo is a trademark and service mark of Emerson Electric Co Homeowner Help Line 1 800 284 2925 ...