Configuration Menu

Menu Screen 

Number

Displayed 

(Factory Default)

Press 

 or 

 

to select options

01

Sleep

(OFF)

On

Select Sleep Timer On or OFF
If selected OFF, skip to menu screen 04

02

h

(8)

1 to 12

Select 1 to 12 hours for Sleep Timer On.
See Sleep Timer section on page 3

03

CS

(OFF)

On

Select Cool Savings Feature On or OFF
If selected OFF, skip to menu screen 06

04

CS

(3)

1 to 6

Select 1 to 6 for Cool Savings Feature On
See Cool Savings section on page 3

05

CR

(FA)

SL

Select Adjustable Anticipation, cycle rate for Heat Pump, Heat 
and Cool. See table below 

06

CR

 Aux

(FA)

FA

Select Adjustable Anticipation, cycle rate for Aux./Emer Heat. 
See table below

07

CL

(OFF)

On

Select Compressor Lockout OFF or On. When selected On,  
the thermostat will wait 5 minutes before turning the 
compressor on.

08

L

(On)

OFF

Select Display Light On of OFF. When selected On and the “C” 
terminal is connected, the backlight will stay on continuously. 
When OFF the backlight will come on for a short time when any 
key is pressed.

09

Room Temp

(0)

4 LO to 

4 HI

Select room temperature display for 4

o

 higher or 4

lower than 

the actual temperature

10

o

F

o

C

Select 

o

F or 

o

C Display (temperature displayed in Fahrenheit or 

Celsius)

11

FH

(On)

OFF

Select fast second stage On or OFF

12

Change Filter

(OFF)

On

Select filter maintenance indicator OFF or On.
If selected OFF, item B will be skipped

13

Change Filter

(200 h)

25 to 1975

Select 25 to 1975 hours for Change Filter reminder 
See Change Filter reminder section on page 3

Menu Navigation

Press 

 for next. Press 

 to go back

To exit the menu: 

Set the system switch to Cool or Heat. If 

no keys are pressed within fifteen minutes, the thermostat will 
revert to normal operation.

 

 Installation

Select Configuration Options

The configuration menu allows you to set certain thermostat operating characteristics to your system or personal requirements.  

Select Cycle Rate – 

The cycle rate can be adjusted to keep 

the heat or cool on longer or shorter to match the temperature 
response of the home with your heating and cooling system.

 

MODE  Fast Slow

  

(FA) 

(SL)

 

Heat Pump 

1.2

o

F 1.7

o

F  

 

Aux./Emer Heat 

.8

o

F 1.2

o

F

Enter Menu

 

   

SYSTEM

              

Press 
and hold
for 3 seconds

Set at

Home

  

 

 

Summary of Contents for 1F89EZ-0251

Page 1: ...NO 37 7208B Replaces 37 7208A 1106 Message to Homeowner Congratulations on choosing the Emerson Blue Easy Set Thermostat The Easy Set is designed to be the easiest thermostat you have ever used This thermostat features Home Sleep and Away temperature pre sets Just press the button and go Included with the easy set is the same temperature accuracy and reliability you expect from all the Emerson Blu...

Page 2: ...ervice indicatesadiagnosticfaultintheheating cooling system It does not indicate a fault in the thermostat 13 indicates power level of batteries Change indicates batteries should be replaced 14 AUX indicates auxiliary stage is operating 15 EMER is displayed flashing when the system switch is in EMER position Batteries Two AA alkaline batteries are included with your thermostat Prior to use open th...

Page 3: ... Savings enabled the thermostat will make small adjustments to the desired temperature during periods of high demand to reduce cooling system running time and save energy When the cooling system has been running for more than 20 minutes humidity in the home will be lower and a higher temperature will feel comfortable After 20 minutes of run time the thermostat will start increasing the desired tem...

Page 4: ...ngeover relay in HEAT the O B switch must be moved to the B position Check Thermostat Operation Heating System 1 Move SYSTEM switch to HEAT position If the heating system has a standing pilot be sure to light it 2 Press to adjust thermostat setting to 1 above room temperature The heating system should begin to operate 3 Press to adjust temperature setting below room temperature The heating system ...

Page 5: ...y is pressed 09 Room Temp 0 4 LO to 4 HI Select room temperature display for 4o higher or 4o lower than the actual temperature 10 o F o C Select o F or o C Display temperature displayed in Fahrenheit or Celsius 11 FH On OFF Select fast second stage On or OFF 12 Change Filter OFF On Select filter maintenance indicator OFF or On If selected OFF item B will be skipped 13 Change Filter 200 h 25 to 197...

Page 6: ...lacement Set System Switch to Cool and lower setpoint below room temperature Verify thermostat and system wires are securely attached Same procedure as diagnostic for No Heat condition except set the thermostat to Cool and lower the setpoint below the room temperature There may be up to a five minute delay before the thermostat clicks in Cooling if the compressor lock out option is selected in the...

Page 7: ...MOSTAT APPLICATION GUIDE Thermostat Configuration Options Thermostat Applications Maximum Stages Heat Cool Heat Pump 1 Single Stage Compressor Heat Pump HP Single Stage Compres sor Heat Pump Systems with Aux Emergency Heat 2 1 Specifications Electrical Rating Battery Power or Hardwire 20 to 30 VAC 50 60 Hz or DC Terminal Load 1 5 A per terminal 2 5 A maximum all terminals combined Setpoint Range 4...

Page 8: ...www white rodgers com www emersonclimate com White Rodgers is a division of Emerson Electric Co The Emerson logo is a trademark and service mark of Emerson Electric Co Homeowner Help Line 1 800 284 2925 ...

Reviews: