background image

2

Get to know your thermostat 

Before you begin using your thermostat, you should be familiar 
with its features and with the display and the location and 
operation of the thermostat buttons and switches. 

The Thermostat Buttons and Switches

1

  Raises temperature setting.

2

  Lowers temperature setting.

3

  Easy Temperature pre-sets 

(Home, Sleep, Away)

.

4

  SYSTEM switch 

(COOL, OFF, HEAT, EMER)

.

5

  FAN switch 

(ON, AUTO)

.

The Display

6

  Indicates desired temperature. This is blank when 

system switch is in the OFF position. Desired 
temperature is displayed (flashing) if the thermostat is in 
lockout mode. 

7

 

“Save”

 indicates the Cool Savings feature is enabled 

in the configuration menu. 

“Save”

 flashing indicates 

Cool Savings feature is operating and saving energy. 

“Save”

 will also flash for 3 seconds after changing the 

temperature to indicate that a pre-set can be saved. 

8

  Indicates system mode. 

Heat icon

 ( ) is displayed when 

the SYSTEM switch is in the HEAT position. Heat icon( )   
is displayed flashing when thermostat is calling for heat. 
Cool icon ( ) is displayed when the SYSTEM switch is in 
the COOL position. Cool icon ( ) is displayed (flashing) if 
the thermostat is calling for cool.

9

  Displays current temperature.

10

 

“Home”, “Sleep”, “Away” 

indicates the easy temperature 

pre-set is enabled.

Figure 1. Thermostat buttons and switches

Set at

Home

2

1

3

4

5

6

10

14

7

9

12

13

11

15

8

Set at

Home Sleep

Away

AUX

EMER

Service

Change

Save

Change Filter

11

 

“Change Filter”

 is displayed when the system has run 

for the programmed filter time period as a reminder to 
change or clean your air filter.

12

 

“Service”

 indicates a diagnostic fault in the heating/cooling 

system. It does not indicate a fault in the thermostat.

13

 “

” indicates power level of batteries. 

“Change 

” 

indicates batteries should be replaced.

14  

“AUX”

 indicates auxiliary stage is operating.

15  

“EMER”

 is displayed flashing when the system switch is 

in EMER position.

Batteries

Two “AA” alkaline batteries are included with your thermostat. 
Prior to use, open the battery door and remove the battery 
tag. We recommend replacing batteries every 2 years, for 
best results, use new premium brand alkaline batteries such 
as Duracell

® 

or Energizer

®

. When battery power remaining is 

approximately half, the 

 will be displayed.

 

 

    Indicates batteries are low

 

 

    and should be replaced

BATTERY LOCATION

             

“AA” Alkaline Batteries

  

  

CAUTION

!

If the home is going to be unoccupied for an extended 
period (over 3 months) and 

 is displayed, the 

batteries should be replaced before leaving. When 
less than two months of battery life remain, the 
setpoint temperature will change by 10 degrees (10 
degrees cooler in Heat / 10 degrees warmer in Cool) 
to alert you to change the batteries before they fail. If 
the temperature change occurs, the normal setpoint 
can be manually reset. However, the temperature will 
change by 10 degrees within two days if the batteries 
are not replaced.

Change

WARNING

!

Do not use on circuits exceeding specified voltage. 
Higher voltage will damage control and could cause 
shock or fire hazard.
Do not short out terminals on gas valve or primary 
control to test. Short or incorrect wiring will damage 

thermostat and could cause personal injury and/or 
property damage.
Thermostat installation and all components of the system 
shall conform to Class II (current limited) circuits per the 
NEC code. Failure to do so could cause a fire hazard.

Summary of Contents for 1F89EZ-0251

Page 1: ...NO 37 7208B Replaces 37 7208A 1106 Message to Homeowner Congratulations on choosing the Emerson Blue Easy Set Thermostat The Easy Set is designed to be the easiest thermostat you have ever used This thermostat features Home Sleep and Away temperature pre sets Just press the button and go Included with the easy set is the same temperature accuracy and reliability you expect from all the Emerson Blu...

Page 2: ...ervice indicatesadiagnosticfaultintheheating cooling system It does not indicate a fault in the thermostat 13 indicates power level of batteries Change indicates batteries should be replaced 14 AUX indicates auxiliary stage is operating 15 EMER is displayed flashing when the system switch is in EMER position Batteries Two AA alkaline batteries are included with your thermostat Prior to use open th...

Page 3: ... Savings enabled the thermostat will make small adjustments to the desired temperature during periods of high demand to reduce cooling system running time and save energy When the cooling system has been running for more than 20 minutes humidity in the home will be lower and a higher temperature will feel comfortable After 20 minutes of run time the thermostat will start increasing the desired tem...

Page 4: ...ngeover relay in HEAT the O B switch must be moved to the B position Check Thermostat Operation Heating System 1 Move SYSTEM switch to HEAT position If the heating system has a standing pilot be sure to light it 2 Press to adjust thermostat setting to 1 above room temperature The heating system should begin to operate 3 Press to adjust temperature setting below room temperature The heating system ...

Page 5: ...y is pressed 09 Room Temp 0 4 LO to 4 HI Select room temperature display for 4o higher or 4o lower than the actual temperature 10 o F o C Select o F or o C Display temperature displayed in Fahrenheit or Celsius 11 FH On OFF Select fast second stage On or OFF 12 Change Filter OFF On Select filter maintenance indicator OFF or On If selected OFF item B will be skipped 13 Change Filter 200 h 25 to 197...

Page 6: ...lacement Set System Switch to Cool and lower setpoint below room temperature Verify thermostat and system wires are securely attached Same procedure as diagnostic for No Heat condition except set the thermostat to Cool and lower the setpoint below the room temperature There may be up to a five minute delay before the thermostat clicks in Cooling if the compressor lock out option is selected in the...

Page 7: ...MOSTAT APPLICATION GUIDE Thermostat Configuration Options Thermostat Applications Maximum Stages Heat Cool Heat Pump 1 Single Stage Compressor Heat Pump HP Single Stage Compres sor Heat Pump Systems with Aux Emergency Heat 2 1 Specifications Electrical Rating Battery Power or Hardwire 20 to 30 VAC 50 60 Hz or DC Terminal Load 1 5 A per terminal 2 5 A maximum all terminals combined Setpoint Range 4...

Page 8: ...www white rodgers com www emersonclimate com White Rodgers is a division of Emerson Electric Co The Emerson logo is a trademark and service mark of Emerson Electric Co Homeowner Help Line 1 800 284 2925 ...

Reviews: