Troubleshooting 

Reset Operation

If a voltage spike or static discharge blanks out the display or 
causes erratic thermostat operation, you may need to reset 
the thermostat. To reset, the System Switch must be in 

Cool, 

HEAT,

 or 

EMER

. Simultaneously hold the 

 and 

 buttons 

for approximately 10 seconds until the display goes blank. If 
the thermostat has power, has been reset and still does not 
function correctly contact your heating/cooling service person 
or place of purchase. 

Symptom

Possible Cause

Corrective Action

No Heat/No Cool/No Fan
(common problems)

1. Blown fuse or tripped circuit breaker.
2. Furnace power switch to OFF.
3. Furnace blower compartment door or  
    panel loose or not properly installed.

Replace fuse or reset breaker.
Turn switch to ON.
Replace door panel in proper position to engage safety 
interlock or door switch. 

No Heat

1. System Switch not set to Heat.

2. Loose connection to thermostat or 
    system
3. Heating System requires service or 
    thermostat requires replacement.

Set System Switch to Heat and raise setpoint above room 
temperature.
Verify thermostat and system wires are securely attached.

Diagnostic: Set System Switch to Heat and raise the 
setpoint above room temperature. Within a five minutes 
the thermostat should make a soft click sound. This sound 
usually indicates the thermostat is operating properly. If 
the thermostat does not click, try the reset operation listed 
above. If the thermostat does not click after being reset 
contact your heating and cooling service person or place of 
purchase for a replacement. If the thermostat clicks, con-
tact the furnace manufacturer or a service person to verify 
the heating system is operating correctly.

No Cool

1. System Switch not set to Cool.

2. Loose connection to thermostat or 
    system.
3. Cooling System requires service or 
    thermostat requires replacement

Set System Switch to Cool and lower setpoint below room 
temperature.
Verify thermostat and system wires are securely attached.
Same procedure as diagnostic for No Heat condition 
except set the thermostat to Cool and lower the setpoint 
below the room temperature. There may be up to a five 
minute delay before the thermostat clicks in Cooling if the 
compressor lock-out option is selected in the configuration 
menu.

Heat, Cool or Fan Runs 
Constantly

1. Possible short in wiring.
2. Possible short in thermostat.
3. Possible short in Heat/Cool/Fan 
    system.
4. Fan Switch set to Fan On.

Check each wire connection to verify they are not shorted 
or touching together. No bare wire should stick out from 
under terminal screws. Try resetting the thermostat as 
described below. If the condition persists, the manufacturer 
of your system or service person can instruct you on how 
to test the Heat/Cool system for correct operation. If the 
system operates correctly, replace the thermostat.

Furnace Cycles Too Fast 
or Too Slow (narrow or 
wide temperature swing)

1. The location of the thermostat and/or 
   the size of the Heating System may be  
   influencing the cycle rate.

The cycle rate adjustment can be found in the configuration 
menu. If an acceptable cycle rate is not achieved using the 
FA (Fast) or SL (Slow) adjustment contact a local service 
person for additional suggestions.

Cooling Cycles Too Fast 
or Too Slow (narrow 
or wide temperature 
swing)

1. The location of the thermostat and/or 
    the size of the Cooling System may 
    be influencing the cycle rate.

The cycle rate for cooling is fixed and can not be adjusted. 
Contact a local service person for suggestions.

Thermostat Setting and 
Thermometer Disagree

1. Thermostat thermometer setting 
    requires adjustment.

The thermometer can be ad/- 4 degrees as listed 
in the Configuration Menu. No other adjustment is possible.

Blank Display and/or 
Keypad Not Responding

1. Voltage Spike or Static Discharge.

If a voltage spike or static discharge occurs use the Reset 
Operation listed above.

Summary of Contents for 1F89EZ-0251

Page 1: ...NO 37 7208B Replaces 37 7208A 1106 Message to Homeowner Congratulations on choosing the Emerson Blue Easy Set Thermostat The Easy Set is designed to be the easiest thermostat you have ever used This thermostat features Home Sleep and Away temperature pre sets Just press the button and go Included with the easy set is the same temperature accuracy and reliability you expect from all the Emerson Blu...

Page 2: ...ervice indicatesadiagnosticfaultintheheating cooling system It does not indicate a fault in the thermostat 13 indicates power level of batteries Change indicates batteries should be replaced 14 AUX indicates auxiliary stage is operating 15 EMER is displayed flashing when the system switch is in EMER position Batteries Two AA alkaline batteries are included with your thermostat Prior to use open th...

Page 3: ... Savings enabled the thermostat will make small adjustments to the desired temperature during periods of high demand to reduce cooling system running time and save energy When the cooling system has been running for more than 20 minutes humidity in the home will be lower and a higher temperature will feel comfortable After 20 minutes of run time the thermostat will start increasing the desired tem...

Page 4: ...ngeover relay in HEAT the O B switch must be moved to the B position Check Thermostat Operation Heating System 1 Move SYSTEM switch to HEAT position If the heating system has a standing pilot be sure to light it 2 Press to adjust thermostat setting to 1 above room temperature The heating system should begin to operate 3 Press to adjust temperature setting below room temperature The heating system ...

Page 5: ...y is pressed 09 Room Temp 0 4 LO to 4 HI Select room temperature display for 4o higher or 4o lower than the actual temperature 10 o F o C Select o F or o C Display temperature displayed in Fahrenheit or Celsius 11 FH On OFF Select fast second stage On or OFF 12 Change Filter OFF On Select filter maintenance indicator OFF or On If selected OFF item B will be skipped 13 Change Filter 200 h 25 to 197...

Page 6: ...lacement Set System Switch to Cool and lower setpoint below room temperature Verify thermostat and system wires are securely attached Same procedure as diagnostic for No Heat condition except set the thermostat to Cool and lower the setpoint below the room temperature There may be up to a five minute delay before the thermostat clicks in Cooling if the compressor lock out option is selected in the...

Page 7: ...MOSTAT APPLICATION GUIDE Thermostat Configuration Options Thermostat Applications Maximum Stages Heat Cool Heat Pump 1 Single Stage Compressor Heat Pump HP Single Stage Compres sor Heat Pump Systems with Aux Emergency Heat 2 1 Specifications Electrical Rating Battery Power or Hardwire 20 to 30 VAC 50 60 Hz or DC Terminal Load 1 5 A per terminal 2 5 A maximum all terminals combined Setpoint Range 4...

Page 8: ...www white rodgers com www emersonclimate com White Rodgers is a division of Emerson Electric Co The Emerson logo is a trademark and service mark of Emerson Electric Co Homeowner Help Line 1 800 284 2925 ...

Reviews: