WOP-2ac-LR2. User manual
39
•
•
•
•
•
•
•
•
•
•
•
To change the SNMP agent parameters, check the box next to 'SNMP'. After this the following parameters will
become available.
roCommunity
–
a password to read the parameters (by default:
public
);
rwCommunity
–
a password to configure (write) parameters (by default:
private
);
TrapSink
–
IP address or domain name of SNMPv1-trap message recipient in HOST [COMMUNITY
[PORT]] format;
Trap2Sink
– IP address or domain name of SNMPv2-trap message recipient in HOST [COMMUNITY
[PORT]] format;
InformSink
– IP address or domain name of Inform message recipient in HOST [COMMUNITY [PORT]]
format;
Sys Name –
device name;
Sys Contact
–
device vendor contact information;
Sys Location
–
device location information;
Trap community
–
password enclosed in traps (default value: trap).
The list of objects which are supported for reading and configuration via SNMP is given below:
eltexLtd.1. 127.1
– monitoring of BS parameters and connected APs;
eltexLtd.1. 127.3
– BS management (reboot).
where eltexLtd – 1.3.6.1.4.1.35265
is Eltex Enterprise identifier.
To apply a new configuration and save setting to non-volatile memory, press 'Apply'. Press 'Cancel' to discard
the changes.