4.3 Test changes mode
The device has a test mode for a test configuration application.
To activate it, press the 'Test changes' button on the top panel of the web interface.
Test mode operating time is 300 seconds (5 minutes). During this time you can navigate through the web
configurator tabs and make any changes by applying them on each page using the 'Apply' button.
After checking the required configuration, press the 'Exit from Test Mode' button and select the desired action:
'Save and exit' – pressing this button will exit the test mode and save to the non-volatile memory all
configuration changes that were made and applied in this mode. It will be impossible to undo changes
made in the test mode.
'Cancel and exit' – pressing will exit the test mode and cancel all changes made in this mode. The
configuration in effect on the device before the test mode is activated will be restored.
If the administrator does not exit the test mode within 300 seconds, this will happen automatically along with a
rollback of all changes that have been made in this mode. After the specified time, the configuration will be
restored even if access to the device is lost as a result of the changes made.