MES53xx, MES33xx, MES23xx Ethernet Switch Series
130
Table 5.127. Global configuration mode commands
Command
Value/Default value
Action
rmon event
index type
[community
com_text
]
[description
desc
_
text
]
[owner
name
]
index: (1..65535);
type: (none, log, trap, log-
trap);
com_text: (0..127)
characters
desc_text: (0..127)
characters
name: string
Configure events used in the remote monitoring system.
-
index
- event index;
-
type
-type of notification generated by the device for this
event:
none - do not create a notification,
log - create a table entry,
trap - send an SNMP trap,
log-trap - create a table entry and send an SNMP trap;
-com_text
- SNMP community string for trap transmission;
-
desc_text
- event description;
-
name
- event creator name.
no rmon event
index
Remove an event used in the remote monitoring system.
rmon alarm
index
mib_object_id interval
rthreshold fthreshold revent
fevent
[type
type
] [startup
direction
] [owner
name
]
index: (1..65535);
mib_object_id: valid OID;
interval: (1..2147483647)
seconds
rthreshold:
(0..2147483647);
fthreshold:
(0..2147483647);
revent: (1..65535);
fevent: (0..65535);
type: (absolute,
delta)/absolute;
startup: (rising, falling,
rising-falling)/rising-falling;
name: string
Configure alarm event trigger criteria.
-
index
- alarm event index;
-
mib_object_id
- variable part identifier of the OID object;
-
interval
- time period when data is collected and compared
to the rising and falling thresholds;
-
rthreshold
- rising threshold;
-
fthreshold
- falling threshold;
-
revent
- event index that is used for crossing the rising
threshold;
- fevent
- event index that is used for crossing the falling
threshold;
-
type
- method for selecting variables and calculating values
to be compared with the thresholds:
absolute
- the absolute value of the selected variable will be
compared to the threshold at the end point of the control
interval;
delta
- the value of the variable selected in the last selection
will be deducted from the current value and the difference will
be compared to the thresholds (the difference between the
variable values at the start and end points of the control
interval);
-
startup
- event generation instruction in the first control
interval; Specify alarm event generation rules for the first
control interval by comparing the selected variable with one
or both thresholds:
-
rising
- generate a single alarm event for the rising threshold
if the selected variable value in the first control interval is
above or equal to this threshold;
-
falling
- generate a single alarm event for the falling
threshold if the selected variable value in the first control
interval is below or equal to this threshold;
-
rising-falling
- generate a single alarm event for the rising
and/or falling threshold if the selected variable value in the
first control interval is above or equal to the rising
threshold/below or equal to the falling threshold;
-
owner
- alarm event creator name.
no rmon alarm
index
Remove an alarm event trigger criterion.
rmon table-size {history
hist_entries
| log
log_entries
}
hist_entries:
(20..32767)/270;
log_entries:
(20..32767)/100
Specify the maximum size for RMON tables.
-
history
- maximum number of rows in the history table;
-
log
- maximum number of rows in the entry table.
A new value will take effect after the switch is
restarted.
no rmon table-size
{history | log}
Set the default value.
Ethernet or port group interface (interface range) configuration mode commands
Command line prompt in the Ethernet or port group interface configuration mode is as follows:
console(config-if)#