MES53xx, MES33xx, MES23xx Ethernet Switch Series
56
Clock is synchronized, stratum 3, reference is 10.10.10.1, unicast
Unicast servers:
Server : 10.10.10.1
Source : Static
Stratum : 3
Status : up
Last Response : 10:37:38.0 UTC Jun 22 2016
Offset : 1040.1794181 mSec
Delay : 0 mSec
Anycast server:
Broadcast:
In the example above, the system time is synchronized with server 10.10.10.1, the last response is
received at 10:37:38; system time mismatch with the server time is equal to 1.04 seconds.
5.8
Configuring time ranges
Commands for configuring the time ranges
console#
configure
console(config)#
time-range
range_name,
where
range_name
– symbolic (1...32) time range identifier
console(config-time-range)#
Table 5.27 – List of time range configuration commands
Command
Value/Default value
Action
absolute {end | start}
hh:mm date month year
hh: (0..23);
mm: (0..59);
date: (1..31);
month: (jan..dec);
year: (2000..2097);
Set the start and (or) the end of the time range in the
following format: hour:minute day month year
no absolute {end | start}
Delete a time range.
periodic list
hh:mm
to
hh:mm
{all |
weekday
}
hh: (0..23);
mm: (0..59);
weekday: (mon…sun)
Set a time range for one weekday or each weekday.
no periodic list
hh:mm
to
hh:mm
{all |
weekday
}
Delete a time range.
periodic
weekday hh:mm
to
weekday hh:mm
hh: (0..23);
mm: (0..59);
weekday: (mon…sun)
Set a time range for a week.
no periodic
weekday
hh:mm
to
weekday hh:mm
Delete a time range.
5.9
Interface configuration
You can specify the mask value in X.X.X.X format or in /N format, where N is the number of
1's in the binary mask representation.
5.9.1
Ethernet, Port-Channel and Loopback interface parameters
Interface configuration mode commands (interface range)