background image

 

 

LEONTON

 

EG5-0702-SFP Series 

(EG5-0702-SFP / EG5-0702-SFP-T)

 

 

 

 

 

User Manual

Summary of Contents for EG5-0702-SFP Series

Page 1: ...LEONTON EG5 0702 SFP Series EG5 0702 SFP EG5 0702 SFP T User Manual ...

Page 2: ...ut not limited to the implied warranties of merchantability and fitness for a particular purpose Leonton Technologies Co Ltd may make improvements and or changes to the product and or specifications of the product described in this manual without prior notice Leonton Technologies Co Ltd will not be liable for any technical inaccuracies or typographical errors found in this guide Changes are period...

Page 3: ...ration FCC Cet équipement a été testé et reconnu conforme aux limites de la classe A pour les équipements numériques conformément à la section 15 des Réglementations FCC Ces limites sont conçues pour fournir une protection raisonnable contre toutes interférences nuisibles dans un milieu résidentiel Cet équipement génère utilise et peut émettre de l énergie de fréquence radio et s il n est pas inst...

Page 4: ...equired to take adequate measures CE Mark Avertissement Ceci est un produit de classe A Dans un environnement domestique ce produit peut être utilisé en présence d interférences radio This document is the current official release manual Please check our website www leonton com for any updated manual or contact us by e mail sales leonton com ...

Page 5: ...3 Front Panel 4 Top View 4 LED Indicators 5 Ethernet Ports 6 Cabling 7 Wiring the Power Inputs 9 Wiring the Fault Alarm Contact 10 Mounting Installation 11 DIN Rail Mounting 11 Wall Mounting in the industrial control panel 13 Hardware Installation 14 Installation Steps 14 Maintenance and Service 15 Trouble Shooting 16 ...

Page 6: ... operating temperature of 40 to 75 C this series is designed to meet any needs for industrial automation outdoor application and harsh environments Key Features Interface Performance All Copper ports support auto MDI MDI X function Embedded 5 10 100 1000Tx and 2 100 1000 SFP Slot Store and forward switching architecture 8K MAC Address Table Supports 9 6Kbytes Jumbo Frame 4Mbits memory buffer Power...

Page 7: ...rial Ethernet switch s hardware specs ports cabling information and wiring installation will be described within this user manual Attention Si la tension CC est fournie par un circuit externe veuillez utiliser un dispositif de protection sur l entrée d alimentation Fourniture par courant industriel homologué UL Les spécifications matérielles les ports les informations de câblage et l installation ...

Page 8: ...3 Hardware Description Physical Dimensions Figure 2 1 below shows the physical dimensions of EG5 0702 SFP series W x D x H is 54mm x 99mm x 142mm Figure 2 1 EG5 0702 SFP series Physical Dimensions ...

Page 9: ... shown below in Figure 2 2 Figure 2 2 The Front Panel of EG5 0702 SFP series Top View Figure 2 3 below shows the top panel of the EG5 0702 SFP series switch that is equipped with one 6 pin removal terminal block connector for dual DC power inputs 12 48VDC Figure 2 3 Top Panel View of EG5 0702 SFP series ...

Page 10: ...ve 2 Port link down Broken MASTER Green On ERPS Owner Mode Ring Master is ready Off ERPS Owner Mode is not active RING Green On ERPS Ring Network is active and works well Flashing ERPS Ring works abnormally or misconfigure Off ERPS Ring Network is not active L A SFP Port 6 7 Green 1000Mbps Amber 100Mbps On Connected to network 100 1000Mbps Flashing Networking is active Off Not connected to network...

Page 11: ...traight Through Cable Pin Number Signal Pin Number Signal Pin Number Signal Pin Number Signal 1 RX 3 TX 1 RX 1 TX 2 RX 6 TX 2 RX 2 TX 3 TX 1 RX 3 TX 3 RX 6 TX 2 RX 6 TX 6 RX Table 2 2 1000BASE T RJ 45 Pin Assignments Table 2 3 Crossover Cable Straight Through Cable Pin Number Signal Pin Number Signal Pin Number Signal Pin Number Signal 1 TP0 3 TP1 1 TP0 1 TP1 2 TP0 6 TP1 2 TP0 2 TP1 3 TP1 1 TP0 3 ...

Page 12: ...at complies with IEC 60825 1 and classified as Class 1 laser product Attention Veuillez utiliser un émetteur récepteur optique SFP conforme à la norme CEI 60825 1 et classé comme produit laser de classe 1 To connect the transceiver and LC cable please follow below steps Step 1 Insert the SFP transceiver module into the SFP slot as shown below in Figure 2 4 Notice that the triangle mark is at the b...

Page 13: ...shown below Step 1 Press the upper side of the LC connector from the transceiver and pull it out to release as shown below in Figure 2 7 Figure 2 7 Remove LC Connector Step 2 Push down the metal clasp and pull the transceiver out by the plastic part as shown below in Figure 2 8 Figure 2 8 Pull Out from the SFP Module ...

Page 14: ...k connector as shown below in Figure 2 9 Figure 2 9 Power Terminal Block Step 2 Tighten the wire clamp screws to prevent the wires from loosening as shown below in Figure 2 10 Figure 2 10 Power Terminal Block Caution Only use copper conductors 125 C tighten to 5 in lbs The wire gauge for the terminal block should range between 18 20 AWG Attention Utilisez uniquement des conducteurs en cuivre 125 C...

Page 15: ...plication example for the fault alarm contact is shown below in Figure 2 11 Figure 2 11 Wiring the Fault Alarm Contact Caution The wire gauge for the terminal block should range between 12 24 AWG If only using one power source jumper Pin 1 to Pin 5 and Pin 2 to Pin 6 to eliminate power fault alarm Attention Le calibre des fils du bornier doit être compris entre 12 et 24 AWG Si vous n utilisez qu u...

Page 16: ...gure 3 1 The Rear Side of the Switch and DIN Rail Bracket Follow the steps below to learn how to hang the industrial Ethernet switch Step 1 Use the screws to install the DIN Rail bracket on the rear side of the industrial Ethernet switch Step 2 To remove the DIN Rail bracket do the opposite from Step 1 Step 3 After the DIN Rail bracket is installed on the rear side of the switch insert the top of ...

Page 17: ...pull down the bracket on to the rail as shown below in Figure 3 3 Figure 3 3 Stable the Switch on DIN Rail Step 5 Check if the bracket is mounted tightly on the rail Step 6 To remove the industrial Ethernet switch from the rail do the opposite from the above steps ...

Page 18: ...ottom of the industrial Ethernet switch Step 3 Use the screws to screw the wall mounting bracket on the industrial Ethernet switch Step 4 Use the hook holes at the corners of the wall mounting bracket to hang the industrial Ethernet switch on the wall Step 5 To remove the wall mount bracket do the opposite from the steps above Figure 3 4 Remove DIN Rail Bracket from the Switch and Install the Wall...

Page 19: ...er to the Wiring the Power Inputs section Please refer to the LED Indicators section for LED light indication Step 5 Prepare the twisted pair straight through category 5 cable for Ethernet connection Step 6 Insert one side of the RJ 45 cable into Media Converter s Ethernet port and on the other side into the networking device s Ethernet port e g switch PC or server The Ethernet port s RJ 45 LED on...

Page 20: ...ll as other cables Be careful when handling them so as to not trip over Do not under any circumstance insert foreign objects of any kind into the heat dissipation holes located in the different faces of the device This may not only harm the internal layout but might cause harm to user as well Do not under any circumstance open the device for any reason Please contact your dealer for any repair nee...

Page 21: ... in identifying problems the Media Converter can be easily monitored with the LED indicators which help to identity if any problems exist Please refer to the LED Indicators section for LED light indication If the power indicator LED does not turn on when the power cord is plugged in the user may have a problem with the power cord Check for loose power connections power losses or surges at the powe...

Reviews: