Volume Conversion Device EK220
©
Elster GmbH
63
- Input 2 is an inactive reporting input (input for report signal):
Value
Setting
Comment
Md.I2
2
Input mode "status input"
MdMI2
3
Monitoring mode: "Signal when SC.I2 < L1.I2"
SC.I2
02:228_0 = "
St.I2
"
Status on Input 2
L1.I2
1
Comparative value
L2.I2
-
(Not used here)
SpI2
0.13_02:1.1 =
I2 Rep.sig.
-
Pointer to message "13" in status 2 (report)
- Input 2 is time-synchronised input:
Value
Setting
Comment
Md.I2
2
Input mode "status input"
MdMI2
5
Monitoring mode: "Time-synchronised input"
SC.I2
02:228_0 = "
St.I2"
Status on Input 2
L1.I2
1
Comparative value
L2.I2
-
(Not used here)
SpI2
0.13_02:1.1 =
I2 Rep.sig.
-
Pointer to message "13" in status 2 (report)
Time synchronisation can occur under the following conditions:
-
There must be a pulse on the input within one minute before or after a full hour. The
deciding factor is the time in the EK220.
-
Only one synchronisation per hour can occur.
St.I3
Status on Input 3
Here the status of Input 3 is displayed which is used as status input:
St.I3
= 0: Input signal is inactive
(terminals open or voltage > 3V)
St.I3
= 1: Input signal is active
(terminals connected through low resistance or voltage < 0.8V)
MdMI3 Mode for monitoring E3
Qu.I3 Source for monitoring E3
L1.I3 Limit 1 E3
SpI3
Status pointer for monitoring E3
By setting these values the following functions can be realised for Input 3 (Input 3
is only used as status input):
- Input 3 is an active warning input (input for warning signal):
Value
Setting
Comment
MdMI3 2
Monitoring mode: "Signal when SC.I3
³
L1.I3"
SC.I3
03:228_0 = "
St.I3
"
Status on Input 3
L1.I3
1
Comparative value
SpI3
0.08_03:1.1 =
I3 Warn.sig.
-
Pointer to message "8" in status 3
- Input 3 is an inactive warning input (e.g. tamper detection):
Value
Setting
Comment
MdMI3 3
Monitoring mode: "Signal when SC.I3 < L1.I3"
SC.I3
03:228_0 = "
St.I3
"
Status on Input 3
L1.I3
1
Comparative value
SpI3
0.08_03:1.1 =
I3 Warn.sig.
-
Pointer to message "8" in status 3
Summary of Contents for EK220
Page 2: ...Volume Conversion Device EK220 2 Elster GmbH ...
Page 110: ...Volume Conversion Device EK220 110 Elster GmbH A 2 Approval for Ex Zone ...
Page 111: ...Volume Conversion Device EK220 Elster GmbH 111 ...
Page 112: ...Volume Conversion Device EK220 112 Elster GmbH ...
Page 113: ...Volume Conversion Device EK220 Elster GmbH 113 ...
Page 114: ...Volume Conversion Device EK220 114 Elster GmbH ...