Volume Conversion Device EK220
28
©
Elster GmbH
b) Two pressure sensors
1
connected to the EK220,
Sel.p2
= 1 ("CT30")
:
AD
Designation / value
Unit
Access Address DC
p
Pressure
bar
-
7:310_1 4
pMin
Lower alarm limit pressure
bar
C
7:3A8_1 8
pMax
Upper alarm limit pressure
bar
C
7:3A0_1 8
MRL.p
Pressure meas. range lower limit bar
C
6:224_1 8
MRU.p
Pressure meas. range upper limit bar
C
6:225_1 8
p.F
Pressure substitute value
bar
S
7:311_1 8
pb
Pressure at base conditions
bar
C
7:312_1 8
Md.p
Pressure mode
-
C
7:317
7
Typ.p
Pressure sensor type
-
C
6:223
8
SNp
Serial no. of pressure sensor
-
C
6:222
8
SMenu p coeff. Submenu pressure coefficients
-
(C)
12:1C1 8
pAdj1
Adjustment value 1 for pressure
bar
C / S 6:260_1 8
pAdj2
Adjustment value 2 for pressure
bar
C / S 6:261_1 8
Prog
Accept pressure adjustment
-
C / S
6:259
2
p.atm
Ambient pressure fixed value
bar
C
6:212_1 8
p.Mes
Pressure measurement
bar
-
6:211_1 4
p.Abs
Absolute pressure measurement bar
-
6:210_1 4
SMenu Press. 2 Submenu pressure sensor 2
-
(C)
13:1C1 8
p2Mes
Pressure 2 measurement
bar
-
7:211_1 4
(Legends: see page 22)
The unit of the various pressure displays can vary depending on the device setting. The
setting of the unit takes place via the WinPADS parameterisation software with the aid of
parameter files. To do this the appropriate lock must be open. Possible units are: bar,
kPa, psi and MPa.
Furthermore, representation as overpressure or absolute pressure is possible. Exceptions
here are the adjustment values for the pressure (pAdj1, pAdj2, p2Ad1 and p2Ad2) and the
atmospheric pressure (p.atm) which are always displayed as absolute pre ssure.
p
Pressure
pMin Lower alarm limit pressure
pMax Upper alarm limit pressure
p
is the pressure which is used for computing the conversion factor (
®
3.6) and
hence the volume at base conditions (
®
3.2).
If the measured pressure
p.Abs
(see below) is within the alarm limits
pMin
and
pMax
, it is used as
p
:
p
=
p.Abs.
.
If p.Abs is located outside the alarm limits, the substitute value p.F (see below) is
used: p = p.F. In addition, disturbance quantities are then counted (
®
3.2, 3.3) and
the message "p Alarm Lim." displayed (
®
page 48).
1
It is only possible to connect two pressure sensors of type CT30!
Summary of Contents for EK220
Page 2: ...Volume Conversion Device EK220 2 Elster GmbH ...
Page 110: ...Volume Conversion Device EK220 110 Elster GmbH A 2 Approval for Ex Zone ...
Page 111: ...Volume Conversion Device EK220 Elster GmbH 111 ...
Page 112: ...Volume Conversion Device EK220 112 Elster GmbH ...
Page 113: ...Volume Conversion Device EK220 Elster GmbH 113 ...
Page 114: ...Volume Conversion Device EK220 114 Elster GmbH ...