Volume Conversion Device EK220
44
©
Elster GmbH
3.8 Status list
The values shown in this list depend on the set the functionality of certification data log
PL
(see page 58):
a) Functionality of certification data log activ,
PL
= 1 ("on")
:
AD
Designation / value
Unit Access Address DC
S.Reg Status register, total
-
(S)
1:101
19
Stat
Momentary register, total
-
-
1:100
5
Clr
Clear status register
-
S
4:130
2
Logb.
Logbook
-
(S)
4:A30
8
AudTr Audit trail
-
(S)
5:A30
8
PLogB Certification data log (calibration logbook)
-
-
9:A30
8
ClrPL
Clear certification data log
-
C
9:A52
2
b) Functionality of certification data log inactiv,
PL
= 0 ("off")
:
AD
Designation / value
Unit Access Address DC
S.Reg Status register, total
-
(S)
1:101
19
Stat
Momentary register, total
-
-
1:100
5
Clr
Clear status register
-
S
4:130
2
Logb.
Logbook
-
(S)
4:A30
8
AudTr Audit trail
-
(S)
5:A30
8
(Legends: see page 22)
S.Reg Status register, total
Stat
Momentary register, total
The EK220 supplies two types of status information: Momentary status (also known
as "status") and the status register.
Messages in the momentary status point to current statuses such as for example, e r-
rors that are present. When the state is no longer present, the corresponding me s-
sage in the momentary status disappears. Manual deletion is not possible.
Alarms, warnings and reports (i.e. messages with numbers in the range from "1" to
"16") are displayed in the momentary statuses.
- In the status register all messages since the last manual clearing are collected. Here,
you can also see what has happened, for example, since the last station inspection.
The messages can be cleared in this list with the command "Clr".
Only alarms and warnings (i.e. messages with numbers in the range from "1" to "8") are
displayed in status registers. Reports are not entered because they identify states
which are not problematical or may even be intended (e.g. "Daylight saving", "Calibra-
tion lock open" or "Data transfer running").
Summary of Contents for EK220
Page 2: ...Volume Conversion Device EK220 2 Elster GmbH ...
Page 110: ...Volume Conversion Device EK220 110 Elster GmbH A 2 Approval for Ex Zone ...
Page 111: ...Volume Conversion Device EK220 Elster GmbH 111 ...
Page 112: ...Volume Conversion Device EK220 112 Elster GmbH ...
Page 113: ...Volume Conversion Device EK220 Elster GmbH 113 ...
Page 114: ...Volume Conversion Device EK220 114 Elster GmbH ...