Volume Conversion Device EK220
©
Elster GmbH
69
3.12.1
Brief summary of output parameterisation
s
Volume pulse output
...........................................................
Md.A..
= 1 or 5
¢
Selection of the volume counter:
- Vb
Volume at base conditions, undisturbed ......
SC.A...
= 0002:300_0
- VbD Volume at base conditions, disturbance quantity
SC.A...
= 0002:301_0
- VbT Volume at base conditions, total quantity.....
SC.A...
= 0002:302_0
- Vm
Actual volume, undisturbed ...........................
SC.A...
= 0004:300_0
- VmD Actual volume, disturbed................................
SC.A...
= 0004:301_0
- VmT Actual volume, total quantity..........................
SC.A...
= 0004:302_0
Setting of the cp value ......................................................
cp.A...
=
...
s
Status output, logic active or inactive
...............................
Md.A..
= 2 or 6
s
or
event output, logic active or inactive
............................ Md.A = 9 or 10
' Selection of status message(s):
- A message in a status
St.1
to
St.9
......................................
SpA...
= 0.mm_0s:1.1 *
- A message in the system status
StSy
...............................
SpA...
= 0.mm_02:2.1 *
- A message in the total status
Stat
.....................................
SpA...
= 0.mm_01:2.1 *
- Message group in a status
St.1
to
St.9
.............................
SpA...
= 1.mm_0s:1.1 *
- Message group in the system status
StSy
.......................
SpA...
= 1.mm_02:2.1 *
- Message group in the total status
Stat
..............................
SpA...
= 1.mm_01:2.1 *
s
Time-synchronised output, logic active or inactive
.........
Md.A..
= 3 or 7
'Setting of the time-point:
- At the start of each month at 0 hrs. ...................................
SC.A...
= 0001:143_0
- At the start of each month at 6 hrs. ...................................
SC.A...
= 0002:143_0
- At the start of each day at 0 hrs.........................................
SC.A...
= 0001:142_0
- At the start of each day at 6 hrs.........................................
SC.A...
= 0002:142_0
- At the beginning of each hour. ...........................................
SC.A...
= 0001:403_0
- At the beginning of each minute. .......................................
SC.A...
= 0001:402_0
- At the beginning of each measurement period.................
SC.A...
= 0004:156_0
s
Continuous pulse (for test)
.................................................
Md.A..
= 99
s
Output switched on
.............................................................
Md.A..
= 4
s
Output switched off
.............................................................
Md.A..
= 0
*
mm
= Message (1...16),
s
= Status number (1...9 for St.1 ... St.9)
Summary of Contents for EK220
Page 2: ...Volume Conversion Device EK220 2 Elster GmbH ...
Page 110: ...Volume Conversion Device EK220 110 Elster GmbH A 2 Approval for Ex Zone ...
Page 111: ...Volume Conversion Device EK220 Elster GmbH 111 ...
Page 112: ...Volume Conversion Device EK220 112 Elster GmbH ...
Page 113: ...Volume Conversion Device EK220 Elster GmbH 113 ...
Page 114: ...Volume Conversion Device EK220 114 Elster GmbH ...