Glue weight software operation
1.
Place balance under valve first(Hardware 4) and record current container weight
2.
Set valve glue output seconds ms
3.
Set glue weight
4.
Set error value, dispense second dispense amount and set dispense weight error tolerance rate (%)
5.
Execute standard weighing: Original coordinate glue output, glue pressure setting(Hardware 1)will impact glue output
amount, Set dispense time from step 2
6.
Glue output’s weight – No glue’s weight = value, write into column
7.
If passes test, will construct backup parameter (Below T3 constructs parameter NG, cannot use if not ticked)
8.
Select H1 or H2 valve renew parameter
9.
Select standard glue amount selection, insert parameter H1 or H2, glue amount calculation standard
10.
Suggested tick: Clean leftover glue before Auto to prevent error