Appendix E: Zone Types
CommPact Installation Manual
152
Appendix E: Zone Types
Normal
A
Normal
zone
is
active
when
the
system
is
armed.
This
zone
generates
a
Burglary
alarm
instantly
when
triggered.
Normal
zones
are
designed
for
detectors
installed
inside
the
protected
site
or
doors/windows
that
are
never
used
to
enter
the
premises.
Event
Group:
Burglary
Entry/Exit
When
the
system
is
armed,
Entry/Exit
zones
initiate
the
entry
delay
when
triggered.
If
the
system
is
not
disarmed
by
the
time
the
entry
delay
expires,
a
Burglary
alarm
is
generated.
These
zones
are
designed
for
detectors
protecting
the
entrance
to
the
protected
site
Event
Group:
Burglary
Follower
If
an
Entry/Exit
zone
is
triggered
first,
Follower
zones
do
not
generate
an
alarm
when
triggered
during
the
entry
delay.
If
the
system
is
not
disarmed
by
the
end
of
the
entry
delay,
the
Follower
zone
generates
an
alarm.
A
Follower
zone
instantly
generates
an
alarm
if
triggered
when
the
entry
delay
is
not
active.
These
zones
are
designed
for
detectors
protecting
the
area
in
which
a
keypad
has
been
installed
or
the
area
crossed
in
order
to
reach
the
keypad.
Event
Group:
Burglary
Panic
Panic
zones
are
always
active.
When
a
Panic
zone
is
triggered,
a
Panic
alarm
is
generated.
This
zone
type
is
designed
for
panic
buttons
that
may
be
pressed
in
a
robbery
situation.
If
the
Bell
option
is
disabled
for
Panic
zones,
in
addition
to
the
siren
not
sounding,
all
forms
of
alarm
indication
from
the
keypad
are
also
disabled.
Event
Group:
Burglary
Medical
Medical
zones
are
always
active.
When
triggered,
Medical
zones
generate
a
Medical
alarm.
These
zones
are
used
typically
with
panic
buttons
that
may
be
pressed
in
the
event
of
a
Medical.
Event
Group:
Medical
Fire
Fire
zones
are
always
active.
When
triggered,
Fire
zones
generate
a
Fire
alarm.
These
zones
are
designed
for
use
with
smoke
detectors
and
panic
buttons
that
may
be
pressed
in
the
event
of
a
fire.
A
Fire
zone
always
activates
the
siren
even
if
the
Bell
option
is
programmed
as
disabled.
Fire
alarms
sound
a
pulsating
siren
to
distinguish
them
from
other
alarms.
Event
Group:
Fire
24Hr
24Hr
zones
are
always
active.
When
triggered,
24Hr
zones
generate
a
Burglary
alarm.
These
zones
are
used
for
applications
that
require
constant
protection.
Event
Group:
Burglary
Summary of Contents for Commpact
Page 84: ...Appendix A Menu Structure CommPact Installation Manual 80 Appendix A Menu Structure ...
Page 85: ...Appendix A Menu Structure CommPact Installation Manual 81 ...
Page 86: ...Appendix A Menu Structure CommPact Installation Manual 82 ...
Page 87: ...Appendix A Menu Structure CommPact Installation Manual 83 ...
Page 88: ...Appendix A Menu Structure CommPact Installation Manual 84 ...
Page 89: ...Appendix A Menu Structure CommPact Installation Manual 85 ...
Page 90: ...Appendix A Menu Structure CommPact Installation Manual 86 ...
Page 160: ......