Appendix B: Transmitter Installation
CommPact Installation Manual
104
Avoid
installing
in
the
corners
of
a
room.
The
EL
‐
2606
is
best
suited
to
rooms
with
moderate
noise.
The
detector
may
not
consistently
detect
cracks
in
the
glass,
bullets
which
break
through
the
glass
or
glass
breaking
around
corners
and
in
other
rooms.
Glassbreak
detectors
should
always
be
backed
up
by
interior
protection.
For best false alarm immunity:
Locate
the
detector
at
least
1.2m
(4
ʹ
)
away
from
noise
sources
(televisions,
speakers,
sinks,
doors,
etc.).
Avoid
rooms
smaller
than
3m
x
3m
(10
ʹ
X
10
ʹ
)
and
rooms
with
multiple
noise
sources.
Do
not
use
where
white
noise,
such
as
air
compressor
noise,
is
present
(a
blast
of
compressed
air
may
cause
a
false
alarm).
Do
not
define
the
zone
as
24Hr.
It
is
recommended
to
register
the
EL
‐
2606
to
a
perimeter
arming
group
that
arms
the
perimeter
doors
and
windows
of
the
premises.
Avoid
humid
rooms
–
the
EL
‐
2606
is
not
hermetically
sealed.
Excess
moisture
can
eventually
cause
a
short
circuit
and
a
false
alarm.
Areas to avoid:
Glass airlocks and glass vestibule
areas
Noisy kitchens
Residential car garages
Small utility rooms
Stairwells
Small bathrooms
Other small acoustically live rooms
For
glass
break
protection
in
such
applications,
use
shock
detectors
on
the
windows
or
window
frames
connected
to
an
EL
‐
2602
universal
transmitter.
Installation Procedure
Figure B- 19: EL-2606 (Cover Off)
1.
Open
the
housing
using
a
small
flat
‐
head
screwdriver
to
separate
the
base
from
the
cover.
2.
Remove
the
insulator
separating
the
battery
from
the
contacts
on
the
battery
holder.
When
you
apply
power
and
the
tamper
switch
is
open,
the
EL
‐
2606
enters
Test
mode
during
which
a
transmission
is
sent
every
few
seconds.
You
can
terminate
Test
mode
by
closing
the
tamper
switch.
Test
mode
is
automatically
terminated
after
approximately
five
minutes.
Due
to
the
occurrence
of
voltage
delay
in
lithium
batteries
that
have
been
in
storage,
the
batteries
may
initially
appear
to
be
dead.
In
this
case,
leave
the
unit
in
Test
mode
for
a
few
minutes
until
the
battery
voltage
level
is
stabilized.
Tamper
Switch
Battery
Holder
Antenna
Terminal
Block
LED
Indicator
Mounting
Knockout
Mounting
Knockout
Acoustic
Sensor
Summary of Contents for Commpact
Page 84: ...Appendix A Menu Structure CommPact Installation Manual 80 Appendix A Menu Structure ...
Page 85: ...Appendix A Menu Structure CommPact Installation Manual 81 ...
Page 86: ...Appendix A Menu Structure CommPact Installation Manual 82 ...
Page 87: ...Appendix A Menu Structure CommPact Installation Manual 83 ...
Page 88: ...Appendix A Menu Structure CommPact Installation Manual 84 ...
Page 89: ...Appendix A Menu Structure CommPact Installation Manual 85 ...
Page 90: ...Appendix A Menu Structure CommPact Installation Manual 86 ...
Page 160: ......