Appendix B: Transmitter Installation
CommPact Installation Manual
114
Mounting a Detector
1.
Select
the
installation
location.
2.
Remove
locking
pin
securing
the
mounting
bracket
to
the
unit
(see
Figure
B
‐
28).
3.
Remove
the
mounting
bracket
from
the
unit
by
rotating
it
counterclockwise.
4.
Use
the
bracket
as
a
template
for
marking
the
mounting
holes
5.
Using
an
appropriate
drill,
drill
two
holes
at
the
marks
and
insert
anchors.
6.
Using
screws
(supplied)
attach
the
bracket
to
the
wall
as
in
Figure
B
‐
28.
7.
Line
up
the
side
slot
of
the
bracket
and
the
detector.
Push
the
detector
onto
the
mounting
bracket
and
turn
it
clockwise
to
fix
it
into
place.
8.
Insert
the
locking
pin
in
order
to
secure
the
mounting
bracket
to
the
detector
(see
Figure
B
‐
28).
9.
Pull
the
detector
outward
to
make
sure
it
is
securely
attached
to
the
mounting
bracket.
This
detector
is
not
suitable
for
installation
in
a
hazardous
location,
as
defined
in
the
national
electrical
code.
Do
not
use
detector
in
an
outlet
controlled
by
a
wall
switch.
Bracket
Screws
Detector
Locking Pin
Battery Compartment
Tamper
Figure B- 28: Smoke Detector Installation
Figure B- 29: Batteries Compartment/Tamper
Red Indicator
When
the
red
LED
indicator
(see
Figure
B
‐
30)
flashes
once
in
30
seconds,
it
indicates
the
detector
is
under
normal
operation.
When
the
red
LED
flashes
very
frequently
and
an
audible
alarm
sounds
simultaneously,
it
indicates
that
the
detector
senses
smoke.
The
red
LED
behaves
according
to
one
of
the
following
set
modes:
Mode
1:
The
red
LED
indicator
will
not
reset
automatically
at
the
end
of
an
alarm
event.
This
means
that
after
the
smoke
chamber
is
cleared,
the
audible
alarm
will
stop
automatically,
but
the
red
LED
indicator
will
continue
to
flash,
until
it
is
manually
restored
by
the
user.
To
restore
–
press
the
test
button
for
2
‐
3
seconds,
the
LED
will
stop
flashing.
Mode
2
(Default):
The
red
LED
will
reset
automatically
at
the
end
of
an
alarm
event.
The
user
can
check
to
which
mode
the
detector
is
defined
and
switch
between
modes.
•
To
check
the
mode,
press
the
Test
button.
The
red
LED
will
light
up.
If
the
red
LED
lights
up
continuously
the
detector
is
in
Mode
1.
If
the
red
LED
is
blinking
the
detector
is
in
Mode
2.
•
To
switch
from
one
mode
to
another,
press
the
Test
button
for
8
seconds.
The
buzzer
will
sound
and
the
red
LED
will
change
its
behavior
either
from
a
continuous
light
to
a
blinking
light
or
from
a
blinking
light
to
a
continuous
light.
Summary of Contents for Commpact
Page 84: ...Appendix A Menu Structure CommPact Installation Manual 80 Appendix A Menu Structure ...
Page 85: ...Appendix A Menu Structure CommPact Installation Manual 81 ...
Page 86: ...Appendix A Menu Structure CommPact Installation Manual 82 ...
Page 87: ...Appendix A Menu Structure CommPact Installation Manual 83 ...
Page 88: ...Appendix A Menu Structure CommPact Installation Manual 84 ...
Page 89: ...Appendix A Menu Structure CommPact Installation Manual 85 ...
Page 90: ...Appendix A Menu Structure CommPact Installation Manual 86 ...
Page 160: ......