Appendix B: Transmitter Installation
CommPact Installation Manual
105
3.
From
the
Programming
menu,
select
Devices,
Zones
[911].
4.
Select
the
zone
to
which
you
want
to
register
the
transmitter;
the
system
initiates
Registration
mode.
When
Save?
appears
on
the
Control
System’s
LCD
display,
press
.
5.
After
registration,
press
the
EL
‐
2606’s
tamper
switch
to
terminate
Test
mode.
6.
Choose
a
suitable
mounting
location
according
to
the
guidelines
in
the
previous
section.
7.
Before
permanently
mounting
the
unit,
test
the
acoustic
detector
and
the
transmitter
from
the
exact
mounting
position.
For
further
information
on
testing
the
acoustic
detector,
refer
to
the
following
section,
Testing
Procedures.
8.
Knock
out
the
required
mounting
holes
on
the
back
cover.
9.
Mount
the
unit
to
the
wall
using
the
mounting
screws
provided.
10.
Write
the
number
of
the
zone
on
the
sticker
provided
and
affix
the
sticker
inside
the
front
cover
for
future
reference.
11.
Close
the
front
cover
making
sure
that
it
snaps
shut.
Testing Procedure
The
Pattern
Recognition
Technology™
of
the
EL
‐
2606
ignores
most
of
the
sounds
that
could
cause
a
false
alarm
(including
glass
‐
break
testers).
In
order
to
test
the
EL
‐
2606,
you
must
set
the
unit
to
Test
mode.
In
Test
mode,
processing
of
the
upper
and
lower
frequencies
is
disabled.
This
means
that
the
EL
‐
2606
is
only
listening
for
mid
‐
range
frequencies
reproduced
by
the
glassbreak
tester.
It’s
these
mid
‐
range
frequencies
that
determine
the
detector’s
range.
In
Normal
mode,
the
tester
will
not
activate
the
detector
unless
held
directly
over
the
detector.
Figure B- 20: Testing the EL-2606
Test
the
detector
using
the
Electronics
Line
GBS7
or
Sentrol
5709C
hand
‐
held
tester.
1.
If
using
the
5709C
tester,
set
the
tester
to
tempered
glass.
The
5709C
tester
has
a
different
setting
for
each
type
of
glass.
The
tester
should
always
be
set
for
tempered
or
laminated
glass
(either
is
correct
and
both
have
the
same
range)
unless
the
installer
is
certain
that
all
the
glass
to
be
protected
is
plate
glass.
2.
Hold
the
tester
speaker
directly
on
top
of
the
detector
and
activate
the
tester;
the
detector
generates
an
alarm
and
then
enters
test
mode
for
one
minute.
When
in
test
mode,
the
LED
on
the
detector
flashes
continuously.
You
can
extend
the
test
mode
time
by
firing
the
tester
at
the
detector
at
least
once
a
minute.
Each
time
the
detector
generates
an
alarm,
it
also
goes
into
Test
mode
for
one
minute.
3.
Hold
the
tester
near
the
surface
of
the
glass
and
aim
the
tester
at
the
EL
‐
2606.
If
drapes
or
blinds
are
present,
test
with
the
hand
‐
held
tester
behind
the
closed
drapes
or
blinds.
Summary of Contents for Commpact
Page 84: ...Appendix A Menu Structure CommPact Installation Manual 80 Appendix A Menu Structure ...
Page 85: ...Appendix A Menu Structure CommPact Installation Manual 81 ...
Page 86: ...Appendix A Menu Structure CommPact Installation Manual 82 ...
Page 87: ...Appendix A Menu Structure CommPact Installation Manual 83 ...
Page 88: ...Appendix A Menu Structure CommPact Installation Manual 84 ...
Page 89: ...Appendix A Menu Structure CommPact Installation Manual 85 ...
Page 90: ...Appendix A Menu Structure CommPact Installation Manual 86 ...
Page 160: ......