Guide to diagnostics of electronic controls EWM10931
2011 SOE/DT-mdm FCPD-dp Quality tb
9/75
599 73 77-37
8
-
Door
safety
interlock
-
Wash solenoid if the water level
in the tub does not cover the
heating element
-
Motor (55 rpm clockwise,
55 rpm anticlockwise, pulse at
250 rpm)
Door closed
Water level above
the heating element
Check for leaks
from the tub
Drum speed in
rpm/10
9
-
Door
safety
interlock
-
Drain
pump
-
Motor up to 650 rpm then at
maximum spin speed (**)
Door closed
Water level lower
than anti-boiling
level for spinning
Drain,
calibration of
analogue
pressure switch
and spin
Drum speed in
rpm/10
10
------- -------
-----
----
11
-
Reading/Deleting
the last alarm
-------
-------
12
÷
16
-
The LEDs, groups of symbols in
the LCD screen and the
backlight of the display are
turned on in sequence
-
Press a button/sensor to turn on
the group of icons in the LCD
screen or the corresponding LED
and the buzzer sounds at the
same time
Always active
User interface
functions
(*)
In most cases, this time is sufficient to check the heating. However, the time can be increased by repeating the phase without draining the
water: pass for a moment to a different phase of the diagnostic cycle and then back to the heating control phase (if the temperature is higher
than 80
°
C, heating does not take place).
(**)
The check at the maximum speed occurs without control of the AGS and no garments must be inside the appliance.