Guide to diagnostics of electronic controls EWM10931
2011 SOE/DT-mdm FCPD-dp Quality-tb
49/75
599 73 77-37
E5C: The Inverter board input voltage is too high (beyond 430V)
E5C
The voltage should stay above 430V for at least 5 seconds
E5C
Checks to perform:
Measure the mains voltage and make
sure it is within the nominal range.
Is the mains voltage correct?
Wait for the mains voltage to return
to nominal conditions and repeat the
diagnostic cycle to check for any
further alarms.
Replace the motor control board and
repeat the diagnostic cycle to check for
any further alarms.
If there are burns on the circuit
board, see page 73
!
Check that all the connectors are correctly inserted
!
NO
Y
E