Guide to diagnostics of electronic controls EWM10931
2011 SOE/DT-mdm FCPD-dp Quality-tb
22/75
599 73 77-37
Run the diagnostic cycle and fill all the trays with watern
(phases 2,3,4,5,6)
Are all the trays filling with water?
E13: Water leaks
E13
Maximum overall water fill time exceeded (sum of all water fills between one drain
phase and the next to avoid exceeding the maximum volume)
E13
Checks to perform:
Repair the drain circuit and repeat
the diagnostic cycle to check for any
further alarms.
Repair the water circuit of the pressure
switch and repeat the diagnostic cycle to
check for any further alarms.
Replace the main circuit board and repeat the diagnostic cycle to check
for any further alarms.
Is the drain pipe positioned
correctly and not causing the
siphon effect?
-(fig.1)-
Is the pressure switch's water circuit
efficient (leaking/clogged)?
-(fig.2)-
Check whether the tap is open, if the
water pressure is too low and make sure the
tubes are connected and not kinked.
Is one or are all the solenoid valves
not working?
Replace the solenoid valve and repeat
the diagnostic cycle to check for any
further alarms.
Is the resistance measurement of the solenoid
valve approximately 3.5÷4.5 k
Ω
? (Measure it
directly on the solenoid valve without wiring)
-(see
fig.3)-
Replace/repair the wiring and repeat
the diagnostic cycle to check for any
further alarms.
Reconnect the connector and measure
approximately 3.5÷4.5 K
Ω
on the solenoid
valve wiring connector on the circuit board side
-(fig.4)-
: Between J7-1 and J7-3 wash
Between J7-4 and J7-6 pre-wash
Between J8-1 and J8-3 third solenoid valve
Between J8-4 and J8-6 hot water
Is the solenoid valve wiring ok?
Replace the main circuit board and repeat
the diagnostic cycle to check for any
further alarms.
Repair the water circuit and repeat
the diagnostic cycle to check for any
further alarms.
Is the washing machine's water
circuit efficient (leaking)?
NO
Y
E
S
Y
E
S
Y
E
S
Y
E
S
NO
NO
NO
N
O
NO
NO
Y
E
S
Y
E
S
Check that all the connectors are correctly inserted
!
If there are burns on the circuit
board, see page 73
!
Y
E
S