Guide to diagnostics of electronic controls EWM10931
2011 SOE/DT-mdm FCPD-dp Quality-tb
53/75
599 73 77-37
Checks to perform:
E62: Overheating during washing
E62
The temperature of the NTC probe exceeds 88 °C for more than 5 mins.
E62
Measure the NTC probe
between terminals J10-4
and J10-5 of the main circuit
board connector. Is the
value correct? (between 5.7
and 6.3 k
Ω
at 20 °C)
Run the diagnostic cycle
and fill with water up to the
door level to make sure the
heating element is
completely submerged.
Measure between the wiring
connector J3-1/J3-2 and the
appliance body.
-(See fig.6)-
Is the circuit open?
Detach the connector and
measure between the
heating element and the
earth contact.
-(See fig.19)-
Is the circuit open?
Replace the heating
element and repeat the
diagnostic cycle to check
for any further alarms.
Check/replace the wiring and repeat the diagnostic cycle to check
for any further alarms.
Detach the connector and
measure the value directly
on the NTC probe.
-(See fig.18)-
Is the value
correct? (between 5.7 and
6.3 k
Ω
at 20 °C)
Replace the heating
element and repeat the
diagnostic cycle to check
for any further alarms.
Replace the circuit board
and repeat the diagnostic
cycle to check for any
further alarms.
Check/replace the wiring and repeat the diagnostic cycle to check
for any further alarms.
Y
E
S
Y
E
S
NO
NO
Y
E
S
Y
E
S
NO
NO
If there are burns on the circuit
board, see page 73
!
Check that all the connectors are correctly inserted
!
Fig. 18
Fig. 6
Fig. 19
MAIN CIRCUIT
BOARD
5.7 ÷ 6.3 k
Ω
(20 °C)
Washing heating element
5.7 ÷ 6.3k
Ω
(20 °C)
∞
Ω
∞
Ω
∞ Ω