Guide to diagnostics of electronic controls EWM10931
2011 SOE/DT-mdm FCPD-dp Quality-tb
66/75
599 73 77-37
EC3: Problem with weight sensor
EC3
No signal or outside the limits
EC3
Checks to perform:
Measure the continuity between
connector J15 (main circuit board
fig.4
) and the weight sensor
connector. Is the wiring ok?
Turn the appliance off and
back on again, enter the
diagnostic cycle.
Does the EC3 alarm
appear again?
MAIN CIRCUIT
BOARD
Replace the shock absorber and
repeat the diagnostic cycle to
check for any further alarms.
Replace the wiring and repeat
the diagnostic cycle to check for
any further alarms.
NO
NO
Y
E
S
0
Ω
Y
E
S
Check that all the connectors are correctly inserted
!
If there are burns on the circuit
board, see page 73
!
Appliance ok.
J16 J1 J1
J10
J1
J4
J8
J7
J6
J1
J5
J3
J9
J1
Fig. 4