Guide to diagnostics of electronic controls EWM10931
2011 SOE/DT-mdm FCPD-dp Quality-tb
60/75
599 73 77-37
Checks to perform:
Checks to perform:
Checks to perform:
E83: Error reading the programme selector code
E83
Selector position code not envisaged by the configuration data or configuration error
E83
E86
E86: Programme selector configuration error
E86
E87
E87: User Interface microcontroller defective
E87
Turn the appliance on, turn
the programme selector to
every setting: wait at least
10 seconds on each of the
settings before moving on to
the next one. Is alarm E83
shown again?
Replace the display board
and repeat the diagnostic
cycle to check for any
further alarms.
Repeat the diagnostic
cycle to check for any
further alarms.
NO
Y
E
S
Replace the display board and run the diagnostic cycle to check for any further alarms.
Check for any friction
between the control panel
and the knob.
Is it difficult to turn the knob?
NO
Y
E
S
Repair the coupling between
the control panel/
selector knob.
Repeat the diagnostic
cycle to check for any
further alarms.
Check that all the connectors are correctly inserted
!
If there are burns on the circuit
board, see page 73
!
If there are burns on the circuit
board, see page 73
!
Check that all the connectors are correctly inserted
!
Check that all the connectors are correctly inserted
!
Replace the display board and run the diagnostic cycle to check for any further alarms.
If there are burns on the circuit
board, see page 73
!