Guide to diagnostics of electronic controls EWM10931
2011 SOE/DT-mdm FCPD-dp Quality-tb
41/75
599 73 77-37
TERMINALS ON
MOTOR TERMINAL
BLOCK
CONTROLS
C.E.SET.
ACC
(SOLE)
NIDEC
ECM
B
1-2
Stator winding
5.0÷5.8
5.0÷5.8
5.0÷5.8
C
2-3
Stator winding
5.0÷5.8
5.0÷5.8
5.0÷5.8
D
3-1
Stator winding
5.0÷5.8
5.0÷5.8
5.0÷5.8
A
MOTORS
4-5
Winding of tachometric
generator
108÷133 169÷207
85÷98
How to check three-phase motors
1) Check the connection blocks (wiring)
and for the presence of any
protruding/kinked terminals.
2) Check for the presence of any
marks/residue/water or detergent
deposits on the motor and where these
come from.
3) Proceed by checking for any
windings/earthed parts or parts with
poor earthing insulation. Use a tester
with a minimum capacity of 40 M
Ω
:
between each individual terminal and
the motor casing, read
∞
(fig.10)
.
4) Proceed by checking each individual
winding according to the following
table
(fig.11)
.
S
= stator
T
= tachometric generator
If there are burns on the circuit
board, see page 73
!
Fig. 11
Fig. 10