Guide to diagnostics of electronic controls EWM10931
2011 SOE/DT-mdm FCPD-dp Quality-tb
14/75
599 73 77-37
5.3 ALARM
SUMMARY
TABLE
Alarm
Description
Possible fault
Machine status/action
Reset
Page
E00
E11
Water fill difficulty during washing
Tap closed or water pressure too low; Drain pipe improperly positioned;
Water fill solenoid valve faulty; Leaks from water circuit on pressure
switch; Pressure switch faulty; Wiring faulty; Main PCB faulty.
Cycle is paused with door locked
START/RESET
20
E13
Water leaks
Drain pipe improperly positioned; Water pressure too low;
Water fill solenoid valve faulty; Water circuit on pressure switch is
leaking/clogged; Pressure switch faulty.
Cycle is paused with door locked
START/RESET
22
E21
Drain difficulty during washing
Drain pipe kinked/clogged/improperly positioned; Drain filter
clogged/dirty; Wiring faulty; Pressure switch faulty; Drain pump rotor
blocked; Drain pump faulty; Main PCB faulty.
Cycle paused
(after 2 attempts)
START
ON/OFF
RESET
24
E23
Faulty triac for drain pump
Wiring faulty; Drain pump faulty; Main PCB faulty.
Safety drain cycle - Cycle stops with
door open.
RESET 26
E24
Malfunction in “Sensing”
circuit on
triac for drain pump
Main circuit board faulty.
Safety drain cycle - Cycle stops with
door unlocked
RESET 28
E31
Malfunction in electronic pressure
switch circuit
Wiring; Electronic pressure switch; Main PCB.
Cycle stops with door locked
RESET
28
E32
Calibration error of the electronic
pressure switch
Drain pipe kinked/clogged/improperly positioned; Solenoid valve
faulty; Drain filter clogged/dirty; Drain pump faulty; Leaks from
pressure switch hydraulic circuit; Pressure switch faulty;
Wiring; main PCB.
Cycle paused
START/RESET
29
E35
Overflow
Water fill solenoid valve faulty; Leaks from water circuit on pressure
switch; Wiring faulty; Pressure switch faulty; Main PCB faulty.
Cycle interrupted. Safety drain cycle.
Drain pump continues to operate (5 min.
on, then 5 min. off. etc.)
RESET 30
E38
Internal pressure chamber is clogged
(water level does not change for at
least 30 sec. of drum rotation)
Motor belt broken; Water circuit on pressure switch clogged.
Heating phase is skipped
RESET
31
E41
Door open
Check whether the door is closed properly;
Wiring faulty; Door safety interlock faulty;
Main circuit board faulty.
Cycle paused
START/RESET
32
E42
Problems with door lock
Wiring faulty; Door safety interlock faulty;
Electrical current leak between heating element and ground;
Main PCB faulty.
Cycle paused
START/RESET
34
E43
Faulty triac supplying power to door
delay system
Wiring faulty; Door safety interlock faulty;
Main circuit board faulty.
(Safety drain cycle)
Cycle blocked
RESET 36
E44
Faulty sensing by door delay system
Main circuit board faulty.
(Safety drain cycle)
Cycle blocked
RESET 37