Guide to diagnostics of electronic controls EWM10931
2011 SOE/DT-mdm FCPD-dp Quality-tb
59/75
599 73 77-37
E74
E74: NTC probe improperly positioned
E74
Checks to perform:
Run
phase 7
of the diagnostic cycle and
wait for the water to fill. Wait in this phase
for five minutes. Switch the appliance off
and measure the value of the NTC probe
between contacts J10-4 and J10-5 of the
wiring connector
-(fig.4)-
.
Is the value below 5 k
Ω
?
Measure the value of the NTC
probe (5.7÷6.3k
Ω
at 20 °C) between
contacts J10-4 and J10-5 of the wiring
connector
-(fig.4)-.
Is the value correct?
(between 5.7 and 6.3 k
Ω
at 20°C)
Is the probe visibly positioned
correctly in its seat?
-(see fig.21)-
Reposition the probe in its seat and
repeat the diagnostic cycle to check for
any further alarms.
Replace the washing heating element
and repeat the diagnostic cycle to check
for any further alarms.
Replace the circuit board and repeat
the diagnostic cycle to check for any
further alarms.
Y
E
S
NO
Y
E
S
NO
Y
E
S
NO
M
A
IN CIRCUIT
BO
ARD
Heating element
Temperature probe
5.
7÷
6.
3k
Ω
(20 °
C
)
5.7÷6.3k
Ω
(20 °C)
∞ Ω
∞
Ω
Fig. 21
J16 J1 J1
J10
J1
J4
J8
J7
J6
J1
J5
J3
J9
J1
Fig. 4
If there are burns on the circuit
board, see page 73
!
Check that all the connectors are correctly inserted
!
Run
phase 9
of the diagnostic cycle,
drain water from the tub
.
!!CAUTION: THE
WATER COULD BE
SCALDING HOT!!
Replace the washing heating element
and repeat the diagnostic cycle to check
for any further alarms.
!
!