Guide to diagnostics of electronic controls EWM10931
2011 SOE/DT-mdm FCPD-dp Quality-tb
28/75
599 73 77-37
Checks to perform:
Checks to perform:
E24
E24: “Sensing” circuit of the component (triac)
controlling the drain pump faulty
E24
E31
E31: The analogue pressure switch provides the main
circuit board with a signal outside the limits
E31
Replace the circuit board and repeat the diagnostic cycle to check for any further alarms.
Measure that the circuit is closed between
J10-1, J10-2, J10-3 and the connector of the
analogue pressure switch (they are three
independent wires)
-(see fig.7)-
.
is the wiring between the main circuit board and
the analogue pressure switch ok and is it
connected correctly on both sides?
Reconnect and/or replace the wiring and
repeat the diagnostic cycle to check for any
further alarms.
Replace the analogue pressure switch and
repeat the diagnostic cycle to check for any
further alarms codes.
Is the appliance displaying the same
alarm code again?
NO
Y
E
S
Y
E
S
Replace the main circuit board and repeat
the diagnostic cycle to check for any
further alarm codes.
Fig. 7
Check that all the connectors are correctly inserted
!
check that all the connectors are correctly inserted
!
If there are burns on the circuit
board, see page 73
!
If there are burns on the circuit
board, see page 73
!
MAIN CIRCUIT
BOARD
Analogue
pressure
switch
0
Ω