SOI/ADL 2009-10
18/63
599 72 40-73
3 DIAGNOSTICS ENV06 / ENV06 AEG / ENV06 CATALOGUE / ENV06
ACTION / ENV06 input
3.1 Acess to diagnostics
1. Press the defined combination key
(START + the nearest key on the left) and keeping them pressed
2.
Switch on the machine rotating the main selector in the 1st position CW.. In
the ENV06 INPUT press the ON / OFF push button
3. Within 5 second phases led blinks and buzzer sounds to give acknowledge of the operation.
ENV06
ENV06 AEG
ENV06 Catalogue
/ action
ENV06 INPUT
3.2 Exiting the diagnostics system
To exit from DIAGNOSTIC mode it’s sufficient to switch off the machine.
According to the machine configuration, it’s possible that the next machine switch on, the electric test cycle
will be activated. To stop it, switch off again the machine.
Moving the main knob in clockwise direction, the following tests will be done:
Position 1
User Interface Test
Purpose of test:
To test the functionality of all leds and switches
Activated components:
All LEDs and LCD (if present)
Behaviour
All led in sequence, pushing a button
correspondent led is lighted on, the key number
is showed on LCD and the buzzer sound. All LCD
icons blink together
Working conditions:
There is any control to run test (always active).