SOI/ADL 2009-10
5/63
599 72 40-73
1 DIAGNOSTICS on dryer EDR 1000 / EDR 2000 / EDR2000 JEWEL / EDR
2000 CLUB DISPLAY
1.1 Access to diagnostics
EDR 1000
EDR 2000
EDR 2000 JEWEL
EDR 2000 CLUB DISPLAY
1. The appliance must be switched OFF.
2. Press START/PAUSE and the option buttons simultaneously.
3. Holding these two buttons down, switch the appliance ON by turning the programme selector knob one
position clockwise.
4. Continue to hold down the buttons until the LEDs begin to flash and the buzzer sounds (about 5
seconds).
1.2 Exiting the diagnostics system
To exit the diagnostics system, turn the programme selector knob to
zero
to switch the appliance OFF, then
switch it ON and OFF again.
Selector
position
Components activated
Operating
conditions
Function checked
1
All the LEDs light in sequence.
When a button is pressed, the corresponding
LED lights and the buzzer sounds.
Always activated.
Operation of the user
interface.
2
Floating switch.
Canister fill pump.
Door closed. Max.
time 30 sec. Sump
full (0.7 litres
approx.)
Operation of the
floating switch and
canister fill pump.
3
Motor triac and relay.
Canister fill pump always powered.
Door closed. Max.
time 10 min.
Pump 30 sec.
Controls
counterclockwise
drum rotation.
4
Triac motor in stepping operation.
Door closed. Max.
time 10 min.
Control of clockwise
drum rotation (low
speed for visual
inspection of drum
shell assembly).